Texas Instruments IC MCU 16B MSP430F2002IRSAT VQFN-16 TID MSP430F2002IRSAT 데이터 시트

제품 코드
MSP430F2002IRSAT
다운로드
페이지 93
MSP430F20x3
MSP430F20x2
MSP430F20x1
SLAS491I – AUGUST 2005 – REVISED DECEMBER 2012
Outputs (Ports P1 and P2)
over recommended ranges of supply voltage and operating free-air temperature (unless otherwise noted)
PARAMETER
TEST CONDITIONS
V
CC
MIN
TYP
MAX
UNIT
I
(OHmax)
= -1.5 mA
(1)
2.2 V
V
CC
- 0.25
V
CC
I
(OHmax)
= -6 mA
(2)
2.2 V
V
CC
- 0.6
V
CC
V
OH
High-level output voltage
V
I
(OHmax)
= -1.5 mA
(1)
3 V
V
CC
- 0.25
V
CC
I
(OHmax)
= -6 mA
(2)
3 V
V
CC
- 0.6
V
CC
I
(OLmax)
= 1.5 mA
(1)
2.2 V
V
SS
V
SS
+ 0.25
I
(OLmax)
= 6 mA
(2)
2.2 V
V
SS
V
SS
+ 0.6
V
OL
Low-level output voltage
V
I
(OLmax)
= 1.5 mA
(1)
3 V
V
SS
V
SS
+ 0.25
I
(OLmax)
= 6 mA
(2)
3 V
V
SS
V
SS
+ 0.6
(1)
The maximum total current, I
(OHmax)
and I
(OLmax)
, for all outputs combined should not exceed ±12 mA to hold the maximum voltage drop
specified.
(2)
The maximum total current, I
(OHmax)
and I
(OLmax)
, for all outputs combined should not exceed ±48 mA to hold the maximum voltage drop
specified.
Output Frequency (Ports P1 and P2)
over recommended ranges of supply voltage and operating free-air temperature (unless otherwise noted)
PARAMETER
TEST CONDITIONS
V
CC
MIN
TYP
MAX
UNIT
2.2 V
10
Port output frequency
f
Px.y
P1.4/SMCLK, C
L
= 20 pF, R
L
= 1 k
Ω
(1) (2)
MHz
(with load)
3 V
12
2.2 V
12
f
Port°CLK
Clock output frequency
P2.0/ACLK, P1.4/SMCLK, C
L
= 20 pF
(2)
MHz
3 V
16
(1)
A resistive divider with 2 × 0.5 k
Ω
between V
CC
and V
SS
is used as load. The output is connected to the center tap of the divider.
(2)
The output voltage reaches at least 10% and 90% V
CC
at the specified toggle frequency.
Copyright © 2005–2012, Texas Instruments Incorporated
25