Texas Instruments TPA6139A2EVM Evaluation Module TPA6139A2EVM TPA6139A2EVM 데이터 시트

제품 코드
TPA6139A2EVM
다운로드
페이지 8
www.ti.com
Reference
3.1.2.2
Shutdown Controls
1. Shutdown is controlled by pushbutton S1. Press and hold S1 to place the TPA6139A2 in shutdown.
Release S1 to reactivate the TPA6139A2.
3.1.3
Gain Setting
The gain setting is programmed with the GAIN pin and is latched when the MUTE pin is set high. The
default gain of the TPA6139A2EVM is set to 3.5dB using a 49.9 k
Ω
resistor (R2). The gain resistor can be
adjusted to achieve a gain range from 0 dB to 20 dB. Refer to the datasheet for more details on gain
settings.
3.1.4
Power Up
1. Verify the correct connections as described in
and
Verify the correct voltage setting of the power supply and turn ON the power supply. Proper operation
of the EVM should begin.
2. Adjust the audio signal source as needed.
4
Reference
This section includes the EVM schematic and board layout reference.
3
SLOU308 – January 2011
TPA6139A2 EVM
© 2011, Texas Instruments Incorporated