Microchip Technology DM300023 데이터 시트

다운로드
페이지 22
© 2008 Microchip Technology Inc.
DS80290J-page 1
dsPIC30F1010/202X
The dsPIC30F1010/202X (Rev. A1) devices that you
received were found to conform to the specifications
and functionality described in the following documents: 
• DS70178 – “dsPIC30F1010/202X Family Data 
Sheet”
• DS70157 – “dsPIC30F/33F Programmer’s 
Reference Manual”
• DS70046 – “dsPIC30F Family Reference Manual”
The exceptions to the specifications in the documents
listed above are described in this section. These
exceptions are described for the specific devices listed
below:
• dsPIC30F1010
• dsPIC30F2020
• dsPIC33F2023
The dsPIC30F1010/202X Rev. A1 silicon is identified
by performing a “Reset and Connect” operation to the
device using MPLAB
®
 ICD 2 with MPLAB IDE v7.41.03
or later. The output window will show a successful
connection to the device specified in Configure>Select
Device
.
The errata described in this section will be addressed
in future revisions of silicon.
Silicon Errata Summary
The following list summarizes the errata described in
this document:
1.
PWM Dead Time
If a value less than 0x0010 is written to the DTRx
and ALTDTRx registers, either or both of the
PWMxH and PWMxL outputs will not function.
2.
PWM Duty Cycle
Duty cycle resolution is not 1.1 ns over the entire
duty cycle range.
3.
PWM Triggers 
The PWM Special Event Trigger and PWM
Individual Trigger do not function near the
beginning of the PWM period.
4.
ADC Sample and Hold Timing
The resolution of the PWM to ADC sample and
hold trigger timing is 41.6 ns instead of the 8 ns
specified in the device data sheet.
5.
ADC Interrupts
Individual ADC Interrupts for the ADC pin pairs do
not work.
6.
ADC Shared Sample and Hold Circuit
Depending on conversion configuration, ADC
inputs that do not have dedicated sample and hold
circuits may produce inaccurate conversion results.
7.
ADC Global Software Trigger 
The Global Software Trigger bit (GSWTRG in the
ADCON register) is not reset unless the PxRDY
bits in the ADSTAT register are reset.
8.
RB7 Pin and All Multiplexed Functions
The RB7 pin does not work. This pertains to all
multiplexed functions on RB7 as well.
9.
ADC Conversion Rate
The maximum conversion rate for the ADC module
is 1.5 Msps.
10. Current Reset Mode
Setting the XPRES bit in the PWMCONx register
should enable a current-limit source to reset the
PWM period when the PWM generated is
configured in Independent Time Base mode. This 
functionality is not working correctly.
dsPIC30F1010/202X Rev. A1 Silicon Errata