Microchip Technology MA330019-2 데이터 시트

다운로드
페이지 436
© 2007-2012 Microchip Technology Inc.
DS70292G-page 351
dsPIC33FJ32GP302/304, dsPIC33FJ64GPX02/X04, AND dsPIC33FJ128GPX02/X04
TABLE 30-17: PLL CLOCK TIMING SPECIFICATIONS (V
DD
 = 3.0V TO 3.6V)  
AC CHARACTERISTICS
Standard Operating Conditions: 3.0V to 3.6V (unless otherwise stated)
Operating temperature
-40°C
≤  T
A
 
≤ +85°C for Industrial
-40°C
≤T
A
 
≤+125°C for Extended
Param
No.
Symbol
Characteristic
Min
Typ
(1)
Max
Units
Conditions
OS50
F
PLLI
PLL Voltage Controlled 
Oscillator (VCO) Input 
Frequency Range
0.8
8
MHz ECPLL, HSPLL, XTPLL 
modes
OS51
F
SYS
On-Chip VCO System 
Frequency
100
200
MHz —
OS52
T
LOCK
PLL Start-up Time (Lock Time)
0.9
1.5
3.1
mS
OS53
D
CLK
CLKO Stability (Jitter)
(2)
-3
0.5
3
%
Measured over 100 ms 
period
Note 1: Data in “Typ” column is at 3.3V, 25°C unless otherwise stated. Parameters are for design guidance only 
and are not tested.
2: These parameters are characterized by similarity, but are not tested in manufacturing. This specification is 
based on clock cycle by clock cycle measurements. To calculate the effective jitter for individual time bases 
or communication clocks use this formula:
Peripheral Clock Jitter
D
CLK
F
OSC
Peripheral Bit Rate Clock
--------------------------------------------------------------
------------------------------------------------------------------------
=
For example: Fosc = 32 MHz, D
CLK
 = 3%, SPI bit rate clock, (i.e., SCK) is 2 MHz.
SPI SCK Jitter
D
CLK
32 MHz
MHz
--------------------
------------------------------
3%
16
----------
3%
4
--------
0.75%
=
=
=
=
TABLE 30-18: AC CHARACTERISTICS: INTERNAL RC ACCURACY
AC CHARACTERISTICS
Standard Operating Conditions: 3.0V to 3.6V (unless otherwise stated)
Operating temperature
-40°C
≤  T
A
 
≤ +85°C for Industrial
-40°C
≤T
A
 
≤+125°C for Extended
Param 
No.
Characteristic
Min
Typ
Max
Units
Conditions
Internal FRC Accuracy @ 7.3728 MHz
(1)
F20a
FRC
-2
+2
%
-40°C 
≤  T
A
 
≤  +85°C V
DD
 = 3.0-3.6V
F20b
FRC
-5
+5
%
-40°C 
≤  T
A
 
≤  +125°C V
DD
 = 3.0-3.6V
Note 1: Frequency calibrated at 25°C and 3.3V. TUN bits can be used to compensate for temperature drift.
TABLE 30-19: INTERNAL RC ACCURACY
AC CHARACTERISTICS
Standard Operating Conditions: 3.0V to 3.6V (unless otherwise stated)
Operating temperature
-40°C
≤  T
A
 
≤ +85°C for Industrial
-40°C
≤T
A
 
≤+125°C for Extended
Param
No.
Characteristic
Min
Typ
Max
Units
Conditions
LPRC @ 32.768 kHz
(1)
F21a
LPRC
-20
±6
+20
%
-40°C 
≤  T
A
 
≤  +85°C V
DD
 = 3.0-3.6V
F21b
LPRC
-30
+30
%
-40°C 
≤  T
A
 
≤  +125°C V
DD
 = 3.0-3.6V
Note 1: Change of LPRC frequency as V
DD
 changes.