Microchip Technology DM300023 데이터 시트
dsPIC30F1010/202X
DS70178C-page 178
Preliminary
©
2006 Microchip Technology Inc.
bit 4-0
TRGSRC2<4:0>: Trigger 2 Source Selection bits
Selects trigger source for conversion of analog channels: AN5 and AN4
Selects trigger source for conversion of analog channels: AN5 and AN4
00000
= No conversion enabled
00001
= Individual software trigger selected
00010
= Global software trigger selected
00011
= PWM Special Event Trigger selected
00100
= PWM generator #1 trigger selected
00101
= PWM generator #2 trigger selected
00110
= PWM generator #3 trigger selected
00111
= PWM generator #4 trigger selected
01100
= Timer #1 period match
01101
= Timer #2 period match
01110
= PWM GEN #1 current-limit ADC trigger
01111
= PWM GEN #2 current-limit ADC trigger
10000
= PWM GEN #3 current-limit ADC trigger
10001
= PWM GEN #4 current-limit ADC trigger
10110
= PWM GEN #1 fault ADC trigger
10111
= PWM GEN #2 fault ADC trigger
11000
= PWM GEN #3 fault ADC trigger
11001
= PWM GEN #4 fault ADC trigger
REGISTER 16-6:
A/D CONVERT PAIR CONTROL REGISTER #1 (ADCPC1) (CONTINUED)