Insys GSM EASY 4.1 11-02-01-03-01.027 사용자 설명서

제품 코드
11-02-01-03-01.027
다운로드
페이지 40
INSYS GSM 4.2 easy 
Initial Operation 
January 07 
25
 
4.3 
Troubleshooting 
4.3.1  No response on commands 
INSYS GSM 4.2 easy and the terminal device (configuration PC or controller) have 
to operate the serial interface with the same baud rate and the same data 
format.(Default: 19.200 bps, 8N1
The INSYS GSM 4.2 easy can be reset to the factory settings by pressing the Reset 
key for an extended period (> 25 seconds). 
4.3.2  No connection established 
Check the signal quality of th GSM network. 
Has the INSYS GSM 4.2 easy been logged in? 
Has the SIM card been enabled for incoming data connections? 
Was the phone number for the data connection dialed? 
Is the power supply during sending sufficient?  
4.3.3  Alarm SMS is not dispatched 
Was the SMS service center number entered correctly? 
Was the SMS destination number entered correctly? 
4.3.4  Signal Quality 
The query of the signal quality at the reception location takes place using the 
button Detect GSM field strength now at the tab Basic settings or using the AT 
command AT**SIGNAL?. The response should deliver a value larger than 12; the 
best value would be 31. If you experience difficult signal conditions, change the 
antenna location. The response 99 indicates that no field strength can be detected 
(e.g. for network failure, defective antenna).