Fluke -116/323 Digital Multimeter 4296029 데이터 시트

제품 코드
4296029
다운로드
페이지 24
116 
Users Manual 
18 
General Specifications 
Accuracy is specified for 1 year after calibration, at operating temperatures of 18 
°C to 28 °C, with 
relative humidity at 0 % to 90 %.  
Extended specifications are available at www.Fluke.com. 
Maximum voltage between any  
terminal and earth ground
.......................... 600 V 
Surge Protection ......................................... 6 kV peak per IEC 61010-1600V CAT III,  
Pollution Degree 2 
Display ......................................................... Digital: 6,000 counts, updates 4/sec 
...................................................................... Bar Graph: 33 segments, updates 32/sec 
Temperature ................................................ Operating: -10 °C to + 50 °C 
 
Storage: -40 °C to + 60 °C 
Temperature Coefficient ............................. 0.1 x (specified accuracy)/
°C (<18 °C or >28 °C) 
Operating Altitude....................................... 2,000 meters 
Battery
.......................................................... 9 Volt Alkaline, NEDA 1604A / IEC 6LR61 
Battery Life .................................................. Alkaline: 400 hours typical, without backlight  
Safety Compliances .................................... Complies with ANSI/ISA 82.02.01 (61010-1) 2004, 
CAN/CSA-C22.2 No 61010-1-04, UL 6101B (2003) and 
IEC/EN 61010-1 2
nd
 Edition for measurement Category III, 
600 V, Pollution Degree 2, EMC EN61326-1 
Certifications ............................................... UL, 
P, CSA, TÜV, ; (
N10140), VDE