Freescale Semiconductor Xtrinsic MAG3110 Magnetometer Kit LFSTBEB3110 LFSTBEB3110 데이터 시트

제품 코드
LFSTBEB3110
다운로드
페이지 30
MAG3110
Sensors
Freescale Semiconductor, Inc.
19
5.4
Temperature 
5.4.1
DIE_TEMP (0x0F)
The register contains the die temperature in °C expressed as an 8-bit 2's complement number. The sensitivity of the temperature 
sensor is factory trimmed to 1°C/LSB. The temperature sensor offset is not factory trimmed and must be calibrated by the user 
software if higher absolute accuracy is required. Note: The register allows for temperature measurements from -128°C to 127°C 
but the output range is limited to -40°C to 125°C. The temperature data is updated on every measurement cycle.
 
5.5
Control Registers
5.5.1
CTRL_REG1 (0x10)
Note: Except for STANDBY mode selection (Bit 0, AC), the device must be in STANDBY mode to change any of the fields within 
CTRL_REG1 (0x10).
Table 26. OFF_Y_LSB Register
Bit 7
Bit 6
Bit 5
Bit 4
Bit 3
Bit 2
Bit 1
Bit 0
YD6
YD5
YD4
YD3
YD2
YD1
YD0
0
Table 27. OFF_Z_MSB Register
Bit 7
Bit 6
Bit 5
Bit 4
Bit 3
Bit 2
Bit 1
Bit 0
ZD14
ZD13
ZD12
ZD11
ZD10
ZD9
ZD8
ZD7
Table 28. OFF_Z_LSB Register
Bit 7
Bit 6
Bit 5
Bit 4
Bit 3
Bit 2
Bit 1
Bit 0
ZD6
ZD5
ZD4
ZD3
ZD2
ZD1
ZD0
0
Table 29. TEMP Register
Bit 7
Bit 6
Bit 5
Bit 4
Bit 3
Bit 2
Bit 1
Bit 0
T7
T6
T5
T4
T3
T2
T1
T0
Table 30. CTRL_REG1 Register
Bit 7
Bit 6
Bit 5
Bit 4
Bit 3
Bit 2
Bit 1
Bit 0
DR2
DR1
DR0
OS1
OS0
FR
TM
AC
Table 31. CTRL_REG1 Description
DR[2:0]
Output data rate selection. Default value: 000.
See 
 for more information.
OS [1:0]
This register configures the over sampling ratio for the measurement. The selected number of samples is collected and 
averaged before being placed in the output data registers. The oversampling setting made here applies to both the triggered 
and active modes of operation.
Default value: 00.
See 
 for more information.
FR
Fast Read selection. Default value: 0.
0: The full 16-bit values are read. 
1: Fast Read, 8-bit values read from the MSB registers (Auto-increment skips over the LSB register in burst-read mode).
TM
Trigger immediate measurement. Default value: 0
0: Normal operation based on AC condition. 
1: Trigger measurement.
If part is in ACTIVE mode, any measurement in progress will continue with the highest ODR possible for the selected OSR. 
In STANDBY mode triggered measurement will occur immediately and part will return to STANDBY mode as soon as the 
measurement is complete.
AC
Operating mode selection. Note: see 
 for details. Default value: 0.
0: STANDBY mode. 
1: ACTIVE mode.
ACTIVE mode will make periodic measurements based on values programmed in the Data Rate (DR) and Over Sampling 
Ratio bits (OS).