SAFETY 
INSTRUCTIONS 
Power cord for the United Kingdom 
When using the LCR-800 in the United Kingdom, make sure the 
power cord meets the following safety instructions. 
 
NOTE: This lead/appliance must only be wired by competent persons  
WARNING: THIS APPLIANCE MUST BE EARTHED 
IMPORTANT: The wires in this lead are coloured in accordance with the 
following code: 
Green/ Yellow: 
Earth 
 
Blue: Neutral 
Brown: Live 
(Phase) 
As the colours of the wires in main leads may not correspond with the colours 
marking identified in your plug/appliance, proceed as follows: 
The wire which is coloured Green & Yellow must be connected to the Earth 
terminal marked with the letter E or by the earth symbol  or coloured Green or 
Green & Yellow. 
The wire which is coloured Blue must be connected to the terminal which is 
marked with the letter N or coloured Blue or Black. 
The wire which is coloured Brown must be connected to the terminal marked 
with the letter L or P or coloured Brown or Red. 
If in doubt, consult the instructions provided with the equipment or contact the 
supplier. 
This cable/appliance should be protected by a suitably rated and approved HBC 
mains fuse: refer to the rating information on the equipment and/or user 
instructions for details. As a guide, cable of 0.75mm2 should be protected by a 
3A or 5A fuse. Larger conductors would normally require 13A types, depending 
on the connection method used. 
Any moulded mains connector that requires removal /replacement must be 
destroyed by removal of any fuse & fuse carrier and disposed of immediately, as 
a plug with bared wires is hazardous if a engaged in live socket. Any re-wiring 
must be carried out in accordance with the information detailed on this label.
 
   LCR-800 
User 
Manual 
10
 
G
ETTING STARTED 
This chapter describes the instrument’s main 
features, front & rear panels, power up sequence, 
fixture connections and calibration.  
 
 
Main Features 
Main Features .............................................................. 11
Model comparison ...................................................... 12
Measurement type  Measurement item ...................................................... 12
Measurement combination ......................................... 12
Panel overview 
Front Panel Overview .................................................. 13
Rear Panel Overview .................................................... 16
Setup  
Power Up ..................................................................... 18
Tilt stand ...................................................................... 18
Power up ...................................................................... 18
Fixture connection  Fixture Connection ...................................................... 20
Fixture structure .......................................................... 20
Fixture connection ....................................................... 21
Bias voltage 
connection 
External voltage bias connection ................................ 22
  
Zeroing  
Zeroing ......................................................................... 24