6.9
Transient configuration and status registers
For more information about the uses of the transient function, see application note AN4083, Data Manipulation and Basic 
Settings for Xtrinsic MMA865xFC Accelerometers
. This Transient (HPF) acceleration detection function is similar to the motion 
detection function, except that high-pass filtered data is compared. 
There is an option to disable the high-pass filter through the function. In this case, the behavior is the same as the motion 
detection. This allows for the device to have two motion detection functions.
6.9.1
0x1D: Transient_CFG register
The transient detection mechanism can be configured to raise an interrupt when the magnitude of the high-pass filtered 
acceleration threshold is exceeded. The TRANSIENT_CFG register is used to enable the transient interrupt generation 
mechanism for the three axes (X, Y, Z) of acceleration. There is also an option to bypass the high-pass filter. When the high-pass 
filter is bypassed, the function behaves similar to the motion detection. 
Table 58. 0x1D TRANSIENT_CFG register (Read/Write)
Back to Register Address Map
Bit 7
Bit 6
Bit 5
Bit 4
Bit 3
Bit 2
Bit 1
Bit 0
ELE
ZTEFE
YTEFE
XTEFE
HPF_BYP
Table 59. TRANSIENT_CFG register
Bit(s)
Field
Description
Notes
7–5
Could be 0 or 1.
4
ELE
Transient event flags are latched into the TRANSIENT_SRC 
register

Reading of the TRANSIENT_SRC register clears the event flag. 
0 Event flag latch disabled (default)
1 Event flag latch enabled
3
ZTEFE
Event flag enable for Z-transient acceleration greater than a 
transient threshold event
0 Event detection disabled (default)
1 Raise event flag on measured acceleration delta 
value that is greater than a transient threshold.
2
YTEFE
Event flag enable for Y-transient acceleration greater than a 
transient threshold event
1
XTEFE
Event flag enable for X-transient acceleration greater than 
a transient threshold event
0
HPF_BYP
Bypass high-pass filter
0 Data to transient acceleration detection block is through HPF 
(default)
1 Data to transient acceleration detection block is NOT through 
HPF (similar to motion detection function)