Freescale Semiconductor FRDM-FXS-MULTI 데이터 시트

다운로드
페이지 48
Table 28. INT_SRC_FLAG field descriptions
Field
Description
3
BOOTEND
Boot sequence complete event flag
• Asserted as soon as the device boot sequence has completed.
1: Boot sequence is complete
0: Boot sequence is not complete
2
SRC_FIFO
FIFO event source flag
• Indicates that the FIFO triggered the interrupt
• Cleared by reading the register
1: F_OVF or F_WMKF are set, provided the FIFO interrupt is enabled (
CTRL_REG2[INT_EN_FIFO=1])
0: Cleared by reading the register
1
SRC_RT
Rate threshold event source flag
• Indicates that the rate threshold event flag triggered the interrupt
• Cleared by reading RT_SRC register
0
SRC_DRDY
Data ready event source flag
• Asserted whenever a data-ready event triggers the interrupt
• Cleared whenever the MSB's of the X, Y, and Z axes sample data are read
• Cleared by reading the MSB's of the X, Y, and Z axes sample data
6.8 0x0C: WHO_AM_I
The WHO_AM_I register contains the device identifier which is factory programmed to
0xD1.
Table 29. WHO_AM_I
Bit
7
6
5
4
3
2
1
0
Read
1
1
0
1
0
0
0
1
Write
Reset
1
1
0
1
0
0
0
1
6.9 0x0D: CTRL_REG0
CTRL_REG0 is used for general control and configuration of the device. The bit fields
in CTRL_REG0 should be changed only in Standby or Ready modes. Accuracy of the
output data is not guaranteed if these bits are changed when the device is in Active
mode.
Register Descriptions
32
Xtrinsic 3-Axis Digital Angular Rate Gyroscope, Rev1.2, 7/2014.
Freescale Semiconductor, Inc.