Insys Modem 56k small INT 2.0 11-02-01-01-43.003 사용자 설명서

제품 코드
11-02-01-01-43.003
다운로드
페이지 97
INSYS Modem 56k small INT 2.0/USB 1.0 
S Registry 
June 06 
75 
S4 
Linefeed character 
 
Linefeed character 
 
S5 
Backspace character 
 
Backspace character 
 
S6* 
Waiting period dial tone 
 
Maximum waiting time for the dialing tone. After the modem went off-hook it 
waits 7 seconds for the dialing tone (fixed for approval purposes). If it detects a 
dialing tone during this waiting period it will start dialing. 
 
If it does not detect a dialing tone, it will check if dial tone recognition is activated 
or if the dialing string (Chapter 9 „AT Command Set“, command ATD) contains the 
parameter W. If the dialing tone detection is not activated, the modem waits for 
the dialing tone. The waiting time (in seconds) is specified in S6. 
The value of the S6 registry can be between 4 and 7 seconds.  
 
S7* 
Waiting period carrier signal 
 
Wait for the carrier frequency from the other modem. The maximum time for the 
modem to wait for a response from the other modem is specified in S7. The time 
starts running as soon as the modem has finished dialing. The value of S7 can be 
between 0 and 180 seconds.
 
 
S8* 
Dial tone delay 
 
Dial pause time, if a comma is included in the dialing string. If there is a comma in 
the dialing string, the modem will wait during the dialing procedure, until the 
time specified in S8 (in seconds) has run out. The value of S8 can be between 1 
and 7 seconds. 
 
 
S9* 
Reaction time carrier signal 
 
DCD response time for the carrier frequency from the other modem. The DCD out-
put of the RS232 interface (CT109) of the modem switches to ON, when the carrier 
frequency from the other modem is detected before the time defined in S9 (in 
tenth of seconds) runs out. S9 must be smaller than S10. 
 
 
S10*  Time period between lost carrier signal and hang up 
 
The time which leads to termination after carrier frequency loss. In S10, the time 
is specified in tenth of seconds, which the modem awaits to disconnect, if it 
can’t detect the carrier frequency from the other modem anymore. 
 
 
S12*  Transmission clock of the ESC characters 
 
Minimum pre and post run time and maximum interim time in 1/50 of seconds 
between two characters. This must be observed, if the modem is supposed to de-
tect an abort sequence (usually +++).