Fluke Ti125 , 9 Hz thermography camera, -20 to +350 °C, 160 x 120 pix bolometer matrix 3810330 사용자 설명서

제품 코드
3810330
다운로드
페이지 56
Ti100, Ti105, Ti110, Ti125, TiR105, TiR110, TiR125 
Users Manual 
38 
CNX™ Wireless System 
The Imager supports the Fluke CNX™ Wireless System (may not be available 
in all regions). It can discover up to 10 3000 Series wireless tools up to 20 
meters away. From those 10, you can select 5 tools to view their live 
measurements on the Imager display. 
To discover a supported tool: 
1.  If not already on, turn on each wireless tool and make sure the wireless 
feature is enabled. See the documentation of each tool for more 
information about how to use. 
2.  Turn on the Imager.  
3.  Push . 
4.  Push / to highlight Camera
5.  Push  or  to view the menu. 
6.  Push / to highlight CNX
7.  Push  or  to view the menu. 
8.  Push / to highlight ON
9.  Push  or  start the discovery process. 
When done, the Imager presents a list with the ID and name of available 
tools found within the 20 m distance. 
10.  Push / to highlight a tool name. 
11.  Push  to select the tool. 
12.  Repeat steps 10 and 11 for each tool to show on the display. 
13.  Push  when done. 
The labels change to include an Edit function. By default, the Imager 
shows and saves the data for the selected tools. If these settings are 
acceptable, push  to exit the CNX setup menu.  
To edit the selection: 
14.  Push / to highlight the tool name. 
15.  Push  or  to view the Edit menu. The Edit menu gives you a 
choice to display the measurement data and/or save it to the SD memory 
card. 
16.  Push  to accept the change. 
17.  Push  when done to exit the menu. 
The display updates to show the wireless icon and live measurement for 
each selected wireless tool.