Diagnosis and Testing of the Path
INSYS Modem 336 LL
i-modul Modem 336 LL
10
Aug-06
If the transmission time is still too long, the error correction may be adjusted.
The following adjustment possibilities have an effect on the transient response
when performing an error correction.
when performing an error correction.
¾
Error correction type: V.42 or MNP4 (AT\N)
¾
For MNP4: Block size (AT\A)
If necessary, the error correction may be completely switched off using the com-
mand AT\N0.
mand AT\N0.
Without error correction, however, transfer errors on the line are possible, which
means that the data protocol should be designed in a fail-safe way.
means that the data protocol should be designed in a fail-safe way.
Without error correction, data rates of up to 9,600 baud are possible for good
lines. Higher data rates are not recommended due to the many occurring errors.
For lower line quality, the error frequency will increase significantly according to
the baud rate, if no error correction is used.
lines. Higher data rates are not recommended due to the many occurring errors.
For lower line quality, the error frequency will increase significantly according to
the baud rate, if no error correction is used.