Tandberg Data StorageLibrary T40+, 24 slots, 1xLTO-3 8136-LTO 사용자 설명서

제품 코드
8136-LTO
다운로드
페이지 105
 
52  
Running the Library 
Importing Cartridges via I/E Slot 
 
 Note 
You can import cartridges using either the library interface or the host server 
software application. The instructions included below focus on the library 
interface method for importing cartridges. Please refer to your host application 
documentation if you wish to use the host to import cartridges.  
 
1  Insert cartridges into the I/E station using the Open I/E Slot command on the front panel menu. 
Once the library has performed an inventory of the I/E slots, the user is prompted to assign the 
inserted cartridges to a partition. This assignment can either be performed directly, or postponed 
until later. 
Do not insert cartridges into the I/E station during the library power cycle.  
 
 Note 
There is no hard stop on the import slot. Stop pulling the magazine at the stop 
line indicated on the mail slot label on the top of the magazine. See section 
 in this chapter for more information.
 
 
2.  Assign the cartridges to a partition via the Assign Cartridge command.  
After cartridges are loaded into the I/E station, the I/E station magazine is closed and an inventory 
of the I/E station is performed. A prompt appears on the display asking if you want to assign the 
cartridges to a partition. To begin using cartridges for data storage, cartridges must be assigned to 
a partition. After having selected which partition to assign the unassigned I/E cartridges to, the 
cartridges are ready for use. 
If you select the wrong partition, open the I/E magazine, move the cartridge to a different I/E slot 
and close the I/E magazine. The library re-scans the I/E slots and the Assign Cartridge screen 
appears again. 
3.  Use the Import Cartridge command to physically move the cartridge from the I/E slot to a free 
storage slot in the partition where it is assigned. 
If the library contains multiple partitions, the import operation will not affect operations in other 
partitions. Commands received through the control path of the different partitions will be queued 
and executed when the Import operation has been completed. 
To import media, you need to provide the following information in the Operator interface:  
Partition lists the partitions that you are assigned access to view. 
Cartridges listed include the cartridges that you want to move. 
 
 Note 
Moving cartridges may necessitate updating your host application. Please refer to 
your host application documentation. 
 
The Open I/E can be accessed from the front panel interface only. The assign media and import 
media can be accessed from both the front panel and the remote management interface. 
The paths to open the appropriate screens are:  
 
From the FPI, select Open IE 
 
From the FPI, select Operations > Assign Cartridge 
 
From the FPI, select Operations > Import Cartridge 
 
From the RMI, select Operations > Assign Cartridge 
 
From the RMI, select Operations > Import Cartridge