Tandberg Data StorageLibrary T40+, 24 slots, 1xLTO-3 8136-LTO 사용자 설명서

제품 코드
8136-LTO
다운로드
페이지 105
 
80 
Shipping or Transporting the StorageLibrary 
 
RAS 
Ticket 
Severity 
Level 
Display Message 
Description 
Suggested Action 
6022 
High 
Drive n Tape Alert 
22. Expired 
Cleaning Media. 
The last cleaning 
cartridge used in 
the tape drive is 
worn out. 
Discard the worn out cleaning 
cartridge. 
Wait for the current operation to 
finish. 
Then use a new cleaning 
cartridge. 
6030 
High 
Drive n Tape Alert 
30. Hardware A. 
The tape drive 
has a hardware 
fault. 
Eject the tape. 
Reset the drive. 
Re-start the operation. 
6031 
High 
Drive n Tape Alert 
31. Hardware B. 
The tape drive 
has a hardware 
fault. 
Turn the tape drive off and then 
on again. 
Re-start the operation. 
If the problem persists, call the 
tape drive supplier helpline. 
6032 
High 
Drive n Tape Alert 
32. Interface. 
The tape drive 
has a problem 
with the host 
interface. 
Check the cables and cable 
connections. 
Re-start the operation. 
6034 
High 
Drive n Tape Alert 
34. Download Fail. 
The firmware 
download has 
failed because 
you have tried to 
use the incorrect 
firmware for this 
tape drive. 
Obtain the correct firmware and 
try again. 
6036 
High 
Drive n Tape Alert 
36. Drive 
Temperature. 
Environmental 
conditions inside 
the tape drive are 
outside the 
specified 
temperature 
range 
Verify that the drive CRU fan is 
running. 
6039 
High 
Drive n Tape Alert 
39. Diagnostics 
Required. 
The tape drive 
may have a fault.  
Check for availability of diagnostic 
information and run extended 
diagnostics if applicable. 
Check the tape drive users 
manual for instructions on running 
extended diagnostic tests and 
retrieving diagnostic data