Tandberg Data StorageLibrary T40+, 24 slots, 1xLTO-3 8136-LTO 사용자 설명서

제품 코드
8136-LTO
다운로드
페이지 105
 
StorageLibrary Installation and User Guide 
87 
Table 13. Troubleshooting Matrix - Write or Read Issues with Solution 
Problem 
Solution 
Write or Read Issues 
Contaminated head 
Avoid contamination by ensuring that the library is installed in a 
clean, contamination-free environment. Cartridges should be 
stored vertically in their plastic cases. Continue cleaning the tape 
drive as needed. 
If a cleaning cartridge is not successful in resolving the problem 
after 3 or more attempts, the cleaning cartridge may be 
contaminated and should not be used in another drive. 
Non-acclimatised media 
A cartridge should be acclimatised for at least 24 hours before 
being used, particularly if it has been stored at a substantially 
different temperature or level of humidity than the library. 
Cleaning cartridge is 
Incompatible 
Make sure you are using a permitted cleaning cartridge. 
Expired cleaning cartridge 
Verify the number of cleanings per cleaning cartridge for your 
media type. 
Bad/defective/contaminated 
media 
If the write/read errors persist and the drive has been cleaned, 
that cartridge should be suspected as being defective, unless it is 
an invalid cleaning cartridge. 
If this occurs, export the cartridge and load a known good 
cartridge. In some cases, a cartridge can be worn out, have a 
defective cartridge memory, or it may have been formatted as a 
Firmware Upgrade Tape. 
Any cartridge that is suspected of being defective or 
contaminated should NOT be re-used in any drive. 
 
Table 14. Troubleshooting Matrix - LED Error Messages with Solutions 
Problem 
Solution 
LED Error Messages 
Amber LED on 
When the amber LED is on, the library has encountered an 
electrical or mechanical failure. An error message will be 
displayed on the front panel (and RMI). Please refer to 