Thecus N199 1-bay NAS N199 전단

제품 코드
N199
다운로드
페이지 94
2.  The mapped network drive could not be created because the following 
error has occurred: Multiple connections to a server or shared 
resource by the same user, using more than one user name, are 
not allowed.
 Disconnect all previous connections to the server or shared 
resource and try again. 
 
To check out existing network connections, type net use under the DOS prompt.  
N199 Chassis Feels Hot 
The N199 uses its chassis to dissipate heat, and feeling warm to the touch is 
completely normal. As such, make sure that the N199 is left in a well-ventilated 
area to avoid overheating the unit. 
Restoring Factory Defaults 
From the System menu, choose the Factory Default item and the Reset to 
Factory Default
 screen appears. Press Apply to reset the N199 to factory 
default settings. 
 
 
Resetting to factory defaults will not erase the data stored in the hard disks, but 
WILL revert all the settings to the factory default values. 
WARNING 
 
 
Problems with Time and Date Settings 
The administrator is able to select an NTP Server to keep the N199’s time 
synchronized. However, if the N199 can not access the Internet, you may 
encounter a problem when setting the Time and Time Zone. If this happens: 
  
1.  Login to the Web Administration Interface. 
 
2.  Navigate to System > Time
 
3.  Under NTP Server, select No
 
4.  Set the DateTime, and Time Zone
 
5.  Click Apply
 
In addition, if the N199 is able to access the Internet and you want to keep the 
NTP Server clock.isc.org by default, please make sure the DNS Server is 
correctly, thereby allowing the NTP Server name to correctly resolve. (See 
Network > LAN 1 > DNS Server
Simple Problem Diagnosis Procedure 
This procedure is meant to provide a simple and quick way to identify which part 
of the N199 has failed. 
 
1.  Don’t insert a hard disk into the N199. Attach the power cord and then 
reset the IP address and admin password to the default settings by doing 
the following: 
a)  Power on the N199 and immediately press the Reset button for 10 
seconds. (The Reset button is near the LAN connector) 
b)  This resets the N199 to its default IP address and password 
settings. 
• 
Default IP: 192.168.1.100 
 
 
 
82