Ea Elektro Automatik EA Elektro-Automatik EA-ELR 91000-30 3U Electronic Load 0 - 30 A 0 - 1000 Vdc 0 - 7000 W 33200409 데이터 시트

제품 코드
33200409
다운로드
페이지 160
Page 10
ELR 9000 Series
EA Elektro-Automatik GmbH
Helmholtzstr. 31-33 • 41747 Viersen
Germany
Fon: +49 2162 / 3785-0
Fax: +49 2162 / 16230
1.8.3  Specific technical data
(1 Related to the nominal values, the accuracy defines the maximum deviation between an adjusted values and the true (actual) value.
Example: a 80 V model has min. 0.3% voltage accuracy, that is 240 mV. When adjusting the voltage to 5 V, the actual value is allowed to differ max. 240 mV, which 
means it might be between 4.76 V and 5.24 V.
(2 Typical value at 100% input voltage and 100% power
3) Set values as in the display or as data readable via digital interfaces are more accurate than the corresponding value on the DC input. Their accuracy subtracts 
from the general accuracy. For actual values it is vice versa. There the display accuracy adds to the general accuracy, so the error (i.e. deviation) will be higher.
3.5 kW
Model
ELR 9080-170
ELR 9250-70
ELR 9500-30
ELR 9750-22
AC Input/Output
Input/output voltage
195...253 V L-N
195...253 V L-N
195...253 V L-N
195...253 V L-N
Input/output connection
L,N,PE
L,N,PE
L,N,PE
L,N,PE
Input/output frequency
50/60 Hz ±10%
50/60 Hz ±10%
50/60 Hz ±10%
50/60 Hz ±10%
Input/output fuse (internal)
T16 A
T16 A
T16 A
T16 A
Efficiency 
(2
92.5%
93.5%
94.5%
94.5%
DC Input
Max. input voltage U
Max
80 V
250 V
500 V
750 V
Max. input power P
Max
3500 W
3500 W
3500 W
3500 W
Max. input current I
Max
170 A
70 A
30 A
22 A
Overvoltage protection range
0...1.1 * U
Max
0...1.1 * U
Max
0...1.1 * U
Max
0...1.1 * U
Max
Overcurrent protection range
0...1.1 * I
Max
0...1.1 * I
Max
0...1.1 * I
Max
0...1.1 * I
Max
Overpower protection range
0...1.1 * P
Max
0...1.1 * P
Max
0...1.1 * P
Max
0...1.1 * P
Max
Max. allowed input voltage
100 V
300 V
600 V
850 V
Min. input voltage for I
Max
0.73 V
2.3 V
4.6 V
6.8 V
Temperature coefficient for set 
values Δ / K
Voltage / current: 100 ppm
Voltage regulation
Adjustment range
0...80 V
0...250 V
0...500 V
0...750 V
Stability at ±10% ΔU
AC
< 0.02% U
Max
< 0.02% U
Max
< 0.02% U
Max
< 0.02% U
Max
Stability at ΔI
< 0.05% U
Max
< 0.05% U
Max
< 0.05% U
Max
< 0.05% U
Max
Accuracy 
(1 
(at 23 ± 5°C)
< 0.3% U
Max
< 0.3% U
Max
< 0.3% U
Max
< 0.3% U
Max
Display: Adjustment resolution
Display: Accuracy 
(3
≤ 0.2%
Remote sensing compensation
max. 5% U
Max
Current regulation
Adjustment range
0...170 A
0...70 A
0...30 A
0...22 A
Stability at ±10% ΔU
AC
< 0.05% I
Max
< 0.05% I
Max
< 0.05% I
Max
< 0.05% I
Max
Stability at ΔU
< 0.15% I
Max
< 0.15% I
Max
< 0.15% I
Max
< 0.15% I
Max
Accuracy 
(1 
(at 23 ± 5°C)
< 0.4% I
Max
< 0.4% I
Max
< 0.4% I
Max
< 0.4% I
Max
Display: Adjustment resolution
Display: Accuracy 
(3
≤0.2%
Compensation 10-90% ΔU
DC
< 0.6 ms
< 0.6 ms
< 0.6 ms
< 0.6 ms
Power regulation
Adjustment range
0…3500 W
0…3500 W
0…3500 W
0…3500 W
Stability at ±10% ΔU
AC
< 0.05%
< 0.05%
< 0.05%
< 0.05%
Stability at ΔI / ΔU
< 0.75% P
Max
< 0.75% P
Max
< 0.75% P
Max
< 0.75% P
Max
Accuracy 
(1 
(at 23 ± 5°C)
< 1.25% P
Max
< 1.5% P
Max
< 1.4% P
Max
< 1.5% P
Max
Display: Adjustment resolution
Display: Accuracy 
(3
≤ 0.2%
Resistance regulation
Adjustment range
0.01…12 Ω
0.09…120 Ω
0.42…480 Ω
0.8…1100 Ω
Accuracy
 
(at 23 ± 5°C)
≤2% of max. resistance ± 0.3% of maximum current
Display: Adjustment resolution
Display: Accuracy 
(3
≤0.2%