Hengstler Tico-MFH-100-240VAC-TS-2-RS232 CR0774342 데이터 시트
제품 코드
CR0774342
Data sheet tico 772/773/774
19/07/2012
All rights reserved
Page 3 of 7
Multifunctional counter tico 772/773/774
tico 772/773/774
Counter mode
Unidirectional; adding or subtracting; directional input;
Input A,B
Differential operation, add/sub; totalizing add/add;
phase discriminator single, double or quadruple evaluation
Control input
Reset, gate
Preselect modes
Absolute or trailing, range signal/
limit values (signal 1 <P1, signal 2 >P 2)
Application
Output: prescaler out, preset 0 out, direction out
input/output
Input: additional counter input add/sub, reset, set, gate, keylock,
hold, teach in
Mode
Batch counter with preset or 2nd totalizer with preset
Counter mode
Differential counting add/sub, totalizing add/add
of operation
Measuring principle Period (cycle) measurement (1/tau)
Time base
1/min or 1/s
Min. frequency
1 Hz or 0.1 Hz
Limit values
2 alarms with programmable startup suppression + 1 additional
upper limit value on the application output
Tachometer
Unidirectional add/sub; directional input
mode of operation
Differential add/sub; totalizing add/add;
Phase discriminator single, double or quadruple evaluation
A/B or (A-B)/A
%
Application
Output: Preselect 0 out, direction out
input/output
Input: Additional counter input add/sub, keylock, hold, teach in
Accuracy of the
Time base:
± 30 ppm
tachometer function Measuring principle:
cycle duration measurement
Measuring time:
min. 0.5s/max. 1s or 10s
Measuring resolution:
0.4µs (<30 ppm)
Display resolution:
4 decimal places, 1 digit = 100 ppm
Overall tolerance
= displayed resolution + tolerance of timebase = 130 ppm
Measuring principle Pulse-width or cycle duration measurement
Start input A + Stop input B; Start/Stop key
Time base
Programmable in sec, min, h or hh.mm.ss
Resolution
1; 0.1; 0.01; 0.001; 0.0001
Function
Single-pulse or cumulative measurement
Application
Output:
preset 0 out,
input/output
Input:
additional run, stop, reset, set, keylock, hold,
teach in
TIMER
TACHOMETER
SHIFT COUNTER
BATCH COUNTER
COUNTER