Intended Use
The C-Control BASIC control computer serves for the programmable access of elec-
tric and electronic devices operated with low-voltage safety current. These devices
may be integrated into any technical systems that do not directly or indirectly serve
for medical, health or life-sustaining purposes or whose operation may pose risks to
persons or assets.
You may only use the provided PC software and the P/E Board for programming the
computer.
Safety Notices
Read this section especially careful! Non-compliance with the safety instruc-
tions poses mortal danger due to electric shock or fire!
The C-Control/BASIC control computer MICRO/MICRO-PCP as well as the P/E
Board were subjected to a safety test in accordance with the valid statutory regula-
tions and certified accordingly (CE). With proper handling, this device normally does
not pose a health risk.
AS electronic devices, the C-Control/BASIC control computer MICRO/MICRO-PCP
as well as the P/E Board have to be treated with the usual caution and care. Non-
observance of the listed notices or a utilisation purpose other than the one described
herein may lead to damages or the destruction of the control computer or connected
devices. 
The devices are not protected against flashover and may not be used in high-voltage
current industrial facilities. The maximum input parameters according to the specifi-
cations listed in the Technical Data 
may not be exceeded. You may not operate the devices in rooms or surroundings
with flammable or caustic gasses, vapours or dusts.
You may not commission the devices immediately after bringing them from a cold
into a warm room. The condensation, which may occur, may lead to function disrup-
tions or the breakdown of electronic components on the device.
Avoid strong magnetic fields like in proximity to machines/loudspeakers.
You must establish all electric connections from and to the device prior to connect-
ing the supply voltage. Connecting or disconnecting cables or establishing and dis-
connecting connections to components of the target application during operation
may lead to the destruction of the control computer or the connected devices. 
For supply of the P/E Board, connect a stabilised DC voltage of 8 V to 12 V. Only use
tested laboratory power packs or stabilised power packs. 
35
Beachten Sie bitte, daß während des Zugriffs die interne Uhr weiterläuft. Der Sekun-
denwert sollte daher stets zuerst ausgelesen werden. Steht er auf 59, so muß nach
dem Lesen der letzten interessierenden Zeitinformation
(z.B. HOUR) der Sekundewert nochmals gelesen und auf =O getestet werden. In die-
sem Fall ist das Auslesen der Echtzeituhr zu wiederholen, da eine neue Minute ange-
brochen ist 
Weitergehende Zeitinformationen sind  bei der C-Control MICRO nicht verfügbar,
können aber bei Bedarf  mit einem kleinen Unterprogramm erzeugt werden
GENAUIGKEIT:
Die RTC der C-CONTROL MICRO wird von einem frei laufenden Oszillator gespeist
der Ansprüche für eine genaue Uhr prinzipiell nicht erfüllen kann. Der Hersteller gibt
eine Grundgenauigkeit von 25 % an. Damit aber die RTC aber trotzdem brauchbar
bleibt, haben Sie die Möglichkeit den Takt der Uhr zu kalibrieren.
Das Tool CLOCK_CHECK.BAS hilft Ihnen bei der Kalibrierung und gibt weitere Hin-
weise
FREQ2=Wert
schreibt einen Korrekturfaktor in das Betriebssystem, der den Systemakt um 0,2% je
Digit (ausgehend vom Defaultwert 128, nach dem RESET) korrigiert. Damit lässt sich
der Takt auf 0,2% genau einstellen, was einem Fehler der RTC von 170s/24h ent-
spricht.
Der Inhalt von FREQ2 kann nicht gelesen werden und eine Anweisung wie etwa 
a=FREQ2 
führt zu unkontrollierbarem Fehlverhalten, da das entsprechende TOKEN vom
INTERPRETER der MICRO nicht erkannt wird.
Anmerkung:
YEAR 
MONTH 
DAY 
DOW 
Sind Variablen die für das Betriebssystem reserviert sind, aber bei der MICRO nicht
verwendet werden dürfen.