Atmel SAM4S Xplained Pro Starter and Evaluation Kit ATSAM4S-XPRO ATSAM4S-XPRO 데이터 시트

제품 코드
ATSAM4S-XPRO
다운로드
페이지 1231
1101
SAM4S Series [DATASHEET]
Atmel-11100G-ATARM-SAM4S-Datasheet_27-May-14
43.5
Product Dependencies
43.5.1 Power Management
The user must first enable the DAC Controller Clock in the Power Management Controller (PMC) before using the 
DACC.
The DACC becomes active as soon as a conversion is requested and at least one channel is enabled. The DACC 
is automatically deactivated when no channels are enabled.
For power-saving options, see 
.
43.5.2 Interrupt Sources
The DACC interrupt line is connected to one of the internal sources of the interrupt controller. Using the DACC 
interrupt requires the interrupt controller to be programmed first.
43.5.3 Conversion Performances
For performance and electrical characteristics of the DACC, see the DC Characteristics section of the datasheet.
Table 43-2.
Peripheral IDs
Instance
ID
DACC
30