SAM9N12/SAM9CN11/SAM9CN12 [DATASHEET]
11063K–ATARM–05-Nov-13
• CFDEV: Clock Failure Detector Event
0: No clock failure detection of the main on-chip RC oscillator clock has occurred since the last read of PMC_SR.
1: At least one clock failure detection of the main on-chip RC oscillator clock has occurred since the last read of PMC_SR.
• CFDS: Clock Failure Detector Status
0: A clock failure of the main on-chip RC oscillator clock is not detected.
1: A clock failure of the main on-chip RC oscillator clock is detected.
• FOS: Clock Failure Detector Fault Output Status
0: The fault output of the clock failure detector is inactive.
1: The fault output of the clock failure detector is active.