38.7 Functional Description
38.7.1 Transfer Format
The data put on the TWD line must be 8 bits long. Data is transferred MSB first; each byte must be followed by an 
acknowledgement. The number of bytes per transfer is unlimited (see 
Each transfer begins with a START condition and terminates with a STOP condition (see 
A high-to-low transition on the TWD line while TWCK is high defines the START condition.
A low-to-high transition on the TWD line while TWCK is high defines a STOP condition.
Figure 38-3.  START and STOP Conditions 
Figure 38-4. Transfer Format
38.7.2 Modes of Operation
The TWI has different modes of operations:
Master transmitter mode
Master receiver mode
Multi-master transmitter mode
Multi-master receiver mode
Slave transmitter mode
Slave receiver mode
These modes are described in the following chapters.
TWD
TWCK
Start
Stop
TWD
TWCK
Start
Address
R/W
Ack
Data
Ack
Data
Ack
Stop