LTC2950-1/LTC2950-2
6
295012fd
V
IN
 (Pin 1/Pin 4): Power Supply Input: 2.7V to 26.4V.
PB (Pin 2/Pin 3): Pushbutton Input. Connecting PB to 
ground through a momentary switch provides on/off 
control via the EN/EN pin. An internal 100k pull-up resis-
tor connects to an internal 1.9V bias voltage. The rugged 
PB input can be pulled up to 26.4V externally without 
consuming extra current.
ONT (Pin 3/Pin 2): Additional Adjustable Turn On Time 
Input. Placing an external capacitor to ground determines 
the additional time (beyond the internal default 32ms) 
the PB pin must be held low before the enable output 
is asserted. Floating this pin results in a default turn on 
debounce time of 32ms. 
GND (Pin 4/Pin 1): Device Ground.
INT (Pin 5/Pin 8): Open Drain Interrupt Output. After a 
pushbutton turn-off event is detected, the LTC2950 inter-
rupts the system (µP) by bringing the INT pin low. Once the 
system finishes its power down and housekeeping tasks, 
it sets KILL low, which in turn releases the enable output. 
If at the end of the power down timer (1024ms) KILL is 
still high, the enable output is released immediately. INT 
may optionally be tied to KILL to release the enable output 
immediately after the turn-off event has been detected 
(INT = low).
EN (LTC2950-1, Pin 6/Pin 7): Open Drain Enable Output. 
This pin is intended to enable system power. EN is asserted 
high after a valid PB turn on event. EN is released low if: a) 
KILL is not driven high (by µP) within 512ms of the initial 
valid PB power turn-on event, b) KILL is driven low dur-
ing normal operation, c) a second valid PB event (power 
turn-off) is detected. This pin can connect directly to a 
DC/DC converter shutdown pin that provides an internal 
pull-up. Otherwise a pull-up resistor to an external supply 
is required. The operating range for this pin is 0V to 10V.
EN (LTC2950-2, Pin 6/Pin 7): Open Drain Enable Output. 
This pin is intended to enable system power. EN is asserted 
low after a valid PB turn-on event. EN releases high if: a) 
KILL is not driven high (by µP) within 512ms of the initial 
valid PB power turn-on event, b) KILL is driven low dur-
ing normal operation, c) a second valid PB event (power 
turn-off) is detected. This pin can connect directly to a 
DC/DC converter shutdown pin that provides an internal 
pull-up. Otherwise a pull-up resistor to an external supply 
is required. The operating range of this pin is 0V to 10V.
OFFT (Pin 7/Pin 6): Additional Adjustable Turn Off Time 
Input. A capacitor to ground determines the additional 
time (beyond the internal default 32ms) that the PB pin 
must be held low before initiating a power down sequence 
(INT falling). Floating this pin results in a default turn off 
time of 32ms. 
KILL (Pin 8/Pin 5): KILL Input. Forcing KILL low releases 
the enable output. During system turn on, this pin is blanked 
by a 512ms internal timer to allow the system to pull KILL 
high. This pin has an accurate 0.6V threshold and can be 
used as a voltage monitor input. If unused, connect to a 
low voltage output supply (see Figure 6).
Exposed Pad (Pin 9): Exposed Pad may be left open or 
connected to device ground.