Mikroelektronika MIKROE-442 데이터 시트
mikroBasic PRO for dsPIC30/33 and PIC24
MikroElektronika
509
SPI_Ethernet_24j600_putString
SPI_Ethernet_24j600_putConstString
SPI_Ethernet_24j600_getByte
Prototype
sub function SPI_Ethernet_24j600_putString(dim ptr as ^byte) as word
Description This is MAC module routine. It stores whole string (excluding null termination) into
ENC24J600
RAM
starting from current
ENC24J600
write pointer (
EWRPT
) location.
Parameters -
ptr
: string to be written into
ENC24J600
RAM.
Returns
Number of bytes written into
ENC24J600
RAM.
Requires
Ethernet module has to be initialized. See SPI_Ethernet_24j600_Init.
Example
dim
buffer as string[16]
...
buffer = “mikroElektronika”
...
SPI_Ethernet_24j600_putString(buffer) ‘ put a RAM string into ENC24J600 buffer
Notes
None.
Prototype
sub function SPI_Ethernet_24j600_putConstString(const ptr as ^byte) as word
Description This is MAC module routine. It stores whole const string (excluding null termination) into
ENC24J600
RAM starting from current
ENC24J600
write pointer (
EWRPT
) location.
Parameters -
ptr
: const string to be written into
ENC24J600
RAM.
Returns
Number of bytes written into
ENC24J600
RAM.
Requires
Ethernet module has to be initialized. See SPI_Ethernet_24j600_Init.
Example
const
buffer as string[16]
...
buffer = “mikroElektronika”
...
SPI_Ethernet_24j600_putConstString(buffer) ‘ put a const string into
ENC24J600 buffer
Notes
None.
Prototype
sub function SPI_Ethernet_24j600_getByte() as byte
Description This is MAC module routine. It fetches a byte from address pointed to by current
ENC24J600
read
pointer (
ERDPT
).
Parameters None.
Returns
Returns
Byte read from
ENC24J600
RAM.
Requires
Ethernet module has to be initialized. See SPI_Ethernet_24j600_Init.
Example
dim buffer as byte<>
...
buffer = SPI_Ethernet_24j600_getByte() ‘ read a byte from ENC24J600 buffer
Notes