Renkforce MP 5000 MP-5000 데이터 시트

제품 코드
MP-5000
다운로드
페이지 66
31
Always observe the following safety information before cleaning or servicing the power amplifier:
  Live components may be exposed if covers are opened or components are removed.
 
The device must be disconnected from all power sources before any servicing or repair work is 
carried out.
 
Capacitors inside the device may still carry voltage even though they have been disconnected 
from all power sources.
 
Only qualified experts familiar with the hazards involved and the relevant regulations must per-
form repairs.
a) Fuse replacement
If the fuse must be replaced, observe that only fuses of the indicated type and rated current (see Technical
Data) must be used.
  Never repair fuses or bridge the fuse holder.
•  After the device is disconnected from the mains (pull mains plug!), remove the FUSE holder’s (7) fuse cap
with the defective fuse by turning it carefully.
•  Remove the defective fuse and replace it with a fuse of the same type.
•  Carefully screw the fuse cap with the new fuse back into the FUSE holder (7) now.
•  After this, you can reconnect the device to the mains and take it into operation.
b) Cleaning
Only clean the power amplifier’s outside with a soft, dry cloth or brush.
Never use any aggressive cleaning agents or chemical solutions. They may damage the casing surface.