Finder 072 01 15 Suspended Electrode, 15M 072.01.15 데이터 시트
제품 코드
072.01.15
2
Features
Priority change relay
Special relay for alternating loads,
for applications with pumps, compressors,
air conditioning or refrigeration units
Special relay for alternating loads,
for applications with pumps, compressors,
air conditioning or refrigeration units
•
2 independent NO output, 12 A
•
4 functions
•
2 independent control signals, insulated from
supply
supply
•
110...240 V and 24 V AC/DC supply versions
•
Modular housing, 35 mm wide
•
35 mm rail (EN 60715) mount
•
Cd-free contact material
2 NO (2 DPST-NO)
12 / 20
250 / 400
3,000
1,000
0.55
12 / 0.3 / 0.12
300 (5 / 5)
AgNi
24
110 … 240
0.12
0.18
1.1 / 1.7
1.5 / 3.9
16.8…28.8
90…264
16.8…32
90…264
100 x 10
3
0.2...20
≤ 0.7
50
6
1,000
–20…+50
IP20
•
Multi-function (MI, ME, M2, M1)
Contact specification
Contact configuration
Rated current / Max. peak current
A
Rated voltage / Max. switching voltage V AC (50/60 Hz)
Rated load AC1
VA
Rated load AC15
VA
Single phase motor rating (230 V AC)
kW
Breaking capacity DC1: 30/110/220 V
A
Minimum switching load
mW (V/mA)
Standard contact material
Supply specification
Nominal voltage (U
N
) V AC (50/60 Hz) / DC
Rated power
in stand-by W
with 2 active relays W/VA(50 Hz)
Operating range
V AC (50/60 Hz)
V DC
Technical data
Electrical life at rated load AC1
cycles
Output delay time (T on function diagrams)
s
Power-on activation time
s
Minimum impulse duration
ms
Insulation between supply and contacts (1.2/50 μs) kV
Dielectric strength between open contacts
V AC
Ambient temperature
°C
Protection category
Approvals (according to type)
72 Series - Monitoring relays
72.42
Screw terminal
For outline drawing see page 8
IX-2012, www