Trinamic TMC603-EVAL evaluation Board TMC603-EVAL 데이터 시트

제품 코드
TMC603-EVAL
다운로드
페이지 41
TMC603 DATA SHEET (V. 1.05 / 11. Mar. 2009) 
17 
 
 
Copyright © 2008 TRINAMIC Motion Control GmbH & Co. KG 
HS1
BM1
LS1
220R
GNDP
+V
M
Z 12V
Motor
 
figure 11: parallel Schottky diode avoids current spikes due to bulk diode recovery 
 
5.2.9 
Short to GND detection 
An  ove
rload  condition  of  the  high  side  MOSFET  (“short  to  GND”)  is  detected  by  the  TMC603,  by 
monitoring  the  BM  voltage  during  high  side  on  time.  Under  normal  conditions,  the  high  side  power 
MOSFET reaches the bridge supply voltage minus a small voltage drop during on time. If the bridge is 
overloaded, the voltage cannot rise to the detection level within a limited time, defined by an external 
resistor. Upon detection of an error, the error output is activated. By directly tying it to the enable input, 
the chip becomes disabled upon detection of a short condition and the error flip flop becomes set. 
 
A variation of the short to GND detection delay allows adaptation to the slope control, and modification 
of the sensitivity of the detection during power up. 
 
Short 
detection
Valid area
BMx
BHx
V
VM
-
V
BMS2G
0V
0V
V
VM
t
S2G
BMx voltage 
monitored
Short to GND 
monitor phase
/ERROUT, 
ENABLE
0V
t
S2G
Short detected
delay
delay
inactive
inactive
Short to GND 
detected
Driver off via 
ENABLE pin
 
figure 12: timing of the short to GND detector 
 
Pin 
Comments 
RS2G 
The resistor connected to this pin controls the delay between switching on the high 
side MOSFET and the short to GND check. A 20 µA current out of this pin (resistor 
value of 220 k  to GND) results in a 500 ns delay, a lower current gives a longer 
delay. Disconnecting the pin disables the function. Keep interconnection between IC 
and resistor short, to avoid stray capacitance to adjacent signal traces of modulating 
the set current. 
Resistor range: 47 k  to 1 M  
 
5.2.10  Error logic 
The TMC603 has three different sources for signaling an error: 
 
Undervoltage of the low side supply 
 
Undervoltage of the charge pump 
 
Short to GND detector 
Upon any of these events the error output is pulled low. After a short to GND detector event, the error 
output  remains  active,  until  it  becomes  cleared  by  the  CLR_ERR.  By  tying  the  error  output  to  the 
enable input, the TMC603 automatically switches off the bridges upon an error. The enable input then 
should be driven via an open collector input plus pull-up resistor, or via a resistor.