Panasonic AKT4112100J Temperature Controller KT4 AKT4112100J 데이터 시트
제품 코드
AKT4112100J
KT(AKT4,7,8,9)
3
4. KT7 Series
Note: CT1 or CT2 for current detection is provided as an accessory when heater burn-out alarm function is added.
• Part No.
(Ex) Part No. when the optional function (of Heater burnout alarm: 10A) is added on to the base model are as follows;
Part No.: AKT7111102
• Options
Note: When Current input is specified, a shunt resistor (sold separately) is required.
Base
model
Power
supply
Sensor
input
Control
output
Alarm
output
Heating/
cooling control
Heater
burnout alarm
Communications
function
Description
AKT7
22.5
×
75
×
100mm
1
100 to 240V AC
2
24V AC/DC
1
Multi-input (Thermocouple, RTD, DC Voltage and DC Current)
1
Relay contact output 1a 3A 250V AC
2
Non-contact voltage output (for SSR drive)
3
Current output
1
Open collector output (Alarm output 1)
0
Not available (without Heating/Cooling function)
0
Not available
1
5A (not available for the Current output type) Open collector output
2
10A (not available for the Current output type) Open collector output
3
20A (not available for the Current output type) Open collector output
4
50A (not available for the Current output type) Open collector output
Not available
Not available
1
Available
Product name
Part No.
Shunt resistor (for Current input)
AKT4811
■
PARTS AND FUNCTIONS
• KT4 series
• KT8 series
1
2
3
6
4
5
1
2
3
6
4
5
• KT9 series
• KT7 series
Note: Color selection is the same for each size.
1
2
3
5
4
6
1
2
3
5
4
1
PV display
Indicates PV (process variable).
Indicates PV (process variable).
2
SV display
Indicates SV (setting value).
3
Increase key
Increases numerical value.
Increases numerical value.
4
Decrease key
Decreases numerical value.
Decreases numerical value.
5
Mode key
Switches the setting mode.
Switches the setting mode.
6
OUT/OFF key
Control output is turned on or off when
control output is ON.
Control output is turned on or off when
control output is ON.
KT_new.fm
3 y [ W Q O O Q N P O
P V œ @
j œ @
O P P
P W “