Siemens SPS starter kit 6ED1057-3BA00-0AA8 12 Vdc, 24 Vdc 6ED1057-3BA00-0AA8 데이터 시트
![Siemens](https://files.manualsbrain.com/attachments/fea10bc852adcb1f4f76708d5daebca542e532b9/common/fit/150/50/c53f5738b57089fc3d6c279e23db7450685a19c9616727fc1f659077967b/brand_logo.png)
제품 코드
6ED1057-3BA00-0AA8
Reference material
5.3 Special functions
LOGO!Soft Comfort Online Help
Operating Instructions, 06/2014
Operating Instructions, 06/2014
311
Settings
In addition to the function block inputs and the parameters of the message text, the following
settings provide additional control over the display of message texts:
● Character set selection: You can choose to compose a message text from characters
● Character set selection: You can choose to compose a message text from characters
from the primary character set or the secondary character set. You set the two character
sets from either the "Msg Config" menu on the LOGO! Base Module, or by using the
LOGO!Soft Comfort File → Message Text Settings (Page 52) menu command.
● Message destination: You can choose to display the message text on the
LOGO! onboard display, the LOGO! TDE, or both. If you select the Web server as a
destination, you can display LOGO! message texts through the Web server.
● Ticker setting: The message text can tick or not tick, meaning it can scroll on and off the
display. Two types of message ticking exist:
– Character by character
– Line by line
You can configure each individual line of a message text to tick or not to tick at all. The
– Character by character
– Line by line
You can configure each individual line of a message text to tick or not to tick at all. The
"character by character" or "line by line" setting applies to all lines that you configure to
tick. Select the check box beside a line number to enable ticking for that line. The number