23
1.8
LOGO! with AS-Interface (0BA0-0BA2)
1.8.1
AS-Interface
Introduction
Here in this section, you discover what you must note when using a LOGO! with integrated
AS-Interface.
Converting circuit programs
The LOGO!Soft Comfort converts the circuit programs with AS-Interface inputs (Page 25) or
AS-Interface outputs (Page 25) which were created for previous versions of the modular
LOGO! are converted:
● When you assign a circuit program to a LOGO! Basic via Tools → Select Hardware
● When you assign a circuit program to a LOGO! Basic via Tools → Select Hardware
(Page 90)
● When you download a circuit program without changes to a LOGO! Basic
If you cut one or more AS-Interface inputs or outputs of an older circuit program and pasted
If you cut one or more AS-Interface inputs or outputs of an older circuit program and pasted
them into the circuit program for a LOGO! Basic, the inserted I/O is also converted in the
new circuit program.
Conversion rules
The inputs Ia1 to Ia4 are converted to I13 to I16.
Outputs Qa1 to Qa4 are converted to Q9 to Q12.
After conversion, the info window shows you which AS-Interface I/O was converted to that of
Outputs Qa1 to Qa4 are converted to Q9 to Q12.
After conversion, the info window shows you which AS-Interface I/O was converted to that of
the modular LOGO!. If the conversion is not compatible to your physical hardware structure,
you must adapt the block numbers of the relevant I/O via the block properties dialog.
Additional constants and connecting terminals
Note that LOGO! versions 0BA0 to 0BA2 do not distinguish between standard inputs and
AS-Interface inputs. Due to the modular structure of the devices as of version 0BA3, the
block number of a digital, analog or AS-Interface block is determined by the slot position of
the expansion module.
AS-Interface inputs (Page 25)
The relevant LOGO! versions are also equipped with Ia inputs used for the ASi bus
AS-Interface inputs (Page 25)
The relevant LOGO! versions are also equipped with Ia inputs used for the ASi bus
(Page 25).
Modular LOGO! devices as of the series 0BA3 do not distinguish between normal inputs and
Modular LOGO! devices as of the series 0BA3 do not distinguish between normal inputs and
AS-Interface inputs. The user determines the type of input based on the modules used and
the order in which they are installed. This is why AS-Interface inputs are here displayed only