Hamlin 59025-1-T-02-A 데이터 시트
22
Hamlin USA
Tel: +1 920 648 3000
•
Fax: +1 920 648 3001
•
Email: sales.us@hamlin.com
Hamlin UK
Tel: +44 (0)1379 649700
•
Fax: +44 (0)1379 649702
•
Email: sales.uk@hamlin.com
Hamlin Germany Tel: +49 (0) 6181 953660
•
Fax: +49 (0) 6181 9536666
•
Email: sales.de@hamlin.com
Hamectrol France Tel: +33 (0) 1 4687 0202
•
Fax: +33 (0) 1 4686 6786
•
Email: sales.fr@hamlin.com
TABLE 1
Form A
Normally
Normally Open
Change
Normally
Contact Type
Open
High Voltage
Over
Closed
Switch Type
1
2
3
4
Power
Watt - max.
10
10
5
5
Voltage
Switching
Vdc - max.
200
300
175
175
Breakdown
Vdc - min.
250
450
200
200
Current
Switching
A - max.
0.5
0.5
0.25
0.25
Carry
A - max.
1.2
1.5
1.5
1.5
Resistance
Contact, Initial
Ω - max.
0.2
0.2
0.2
0.2
Insulation
Ω - min.
10
10
10
10
10
9
10
9
Capacitance
Contact
pF - typ.
0.3
0.2
0.3
0.3
Temperature
Operating
°C
-40 to +105
-20 to +105
-40 to +105
-40 to +105
Storage
°C
-65 to +105
-65 to +105
-65 to +105
-65 to +105
Time
Operate
ms - max.
1.0
1.0
3.0
3.0
Release
ms - max.
1.0
1.0
3.0
3.0
Shock
11ms 1⁄2 sine
G - max.
100
100
50
50
Vibration
50-2000 Hz
G - max.
30
30
30
30
TABLE 4
Termination Options:-
SELECT
DESCRIPTION
OPTION
A or F
B
Crimped terminals
C
6.35mm fastons
D
AMP MTE 2.54mm pitch
E
JST XHP 2.5mm pitch
Select Option
S
T
U
V
Switch
Pull In
Activate
Pull In
Activate
Pull In
Activate
Pull In
Activate
Type
AT
Distance
AT
Distance
AT
Distance
AT
Distance
Range
d
Range
d
Range
d
Range
d
(in) mm
(in) mm
(in) mm
(in) mm
1 Normally Open
12-18
(.315)
17-23
(.236)
22-28
(.197)
27-33
(.157)
2 High Voltage
8.0
6.0
5.0
4.0
3 Change Over
15-20
(.276)
20-25
(.216)
25-30
(.177)
4 Normally Closed
7.0
5.5
4.5
CUSTOMER OPTIONS - Switching Specifications
ORDERING INFORMATION
DETAILS PROVIDED ON THIS DATA SHEET ARE PROVIDED FOR
INFORMATION PURPOSES ONLY AND SHOULD NOT BE RELIED
UPON AS BEING ACCURATE FOR ANY PARTICULAR PURPOSE.
Product performance may be affected by the application to which the
product is put. Upon request, HAMLIN will assist purchasers by
providing information specific to any particular application. HAMLIN
disclaims any and all liability whatsoever for any purchaser’s reliance
upon the information contained on this data sheet without further
consultation with authorised representatives of HAMLIN.
INFORMATION PURPOSES ONLY AND SHOULD NOT BE RELIED
UPON AS BEING ACCURATE FOR ANY PARTICULAR PURPOSE.
Product performance may be affected by the application to which the
product is put. Upon request, HAMLIN will assist purchasers by
providing information specific to any particular application. HAMLIN
disclaims any and all liability whatsoever for any purchaser’s reliance
upon the information contained on this data sheet without further
consultation with authorised representatives of HAMLIN.
59036
Switch Type
Table 1
Table 2
Table 3
Sensitivity
Cable Length
Termination
File E61760(N)
www.hamlin.com
X
T
XX
X
TABLE 3
Cable Type:-
24 AWG 7/32 PVC 105
o
C
UL1430/UL1569
Standard Lengths
SELECT
CABLE
OPTION
LENGTH
(in)
mm
01
(3,94) 100
02
(11,81) 300
03
(19,69) 500
04
(29,53) 750
05
(39,37) 1000
TABLE 4
Termination Options:-
SELECT
DESCRIPTION
OPTION
(2
WIRE VERSIONS ILLUSTRATED
)
A
Tinned or untinned leads
B
Crimped terminals
C
6.35mm fastons
D
AMP MTE 2.54mm pitch
E
JST XHP 2.5mm pitch
TABLE 2
Sensitivity Options:-
Activate Distances are approximate
using Hamlin 57025 actuator
as illustrated
Switch AT before modification
Activate Distances are approximate
using Hamlin 57025 actuator
as illustrated
Switch AT before modification
DIMENSIONS (in) mm
CUSTOMER OPTIONS - Sensitivity, Cable Length and Termination Specification
Series 59025
Table 3
Table 2
Table 4
Features
•
2 part magnetically operated
proximity sensor
proximity sensor
•
UL recognised
•
Choice of normally open, normally
closed or change over contacts
closed or change over contacts
•
Customer defined sensitivity
•
Choice of cable length and
connector
connector
Benefits
•
Quick and easy to install
•
No standby power requirement
•
Operates through non-ferrous
materials such as wood, plastic or
aluminium
materials such as wood, plastic or
aluminium
•
Hermetically sealed, magnetically
operated contacts continue to
operate long after optical and other
technologies fail due to
contamination
operated contacts continue to
operate long after optical and other
technologies fail due to
contamination
Applications
•
Position and limit sensing
•
Security
•
Level sensing
•
Linear actuators
X
59025 Firecracker Features and Benefits
A
B
C
Max
Max NOM.
57025
(.245) 6,22
(1.000) 25,40
-
59025
(.245) 6,22
(1.000) 25,40
Table 3 ± (.393) 10,00
Sensor
Actuator
59025
ISSUE No: 4 DATE: 1/5/3
N.B. 57025 actuator sold separately