Wr Rademacher DuoFern 36500172 Wireless wall-mounted switch 36500172 데이터 시트

제품 코드
36500172
다운로드
페이지 40
13
i
EN
DuoFern functions
Value range
Factory setting
A B C D E F G H
26.  End point setting for RADEMACHER 
tubular motors via radio **
-
-
27.  Reset via radio (3-stage)
-
-
28.  Single-button operation
-
-
29.  Jog mode
-
-
30.  Blinds mode 
on / off
Off
31.  Standard slat position * 
/
 #
0 % - 100 %
0 %
32.  auto Tilt after manual stop  
direction "Down" * 
/
 #
on / off
On
33.  auto Tilt in sunshine position *
 /
 #
on / off
Off
34.  auto Tilt in sunshine position * 
/
 #
on / off
Off
35.  auto Tilt after moving to a  
%-position * 
/
 #
on / off
On
36.  Slat run time * 
/
 #
100 ms - 5000 ms
1500 ms (1.5 s)
37.  Motor dead time *
0 ms / 160 ms / 480 ms
0 ms (off)
8.2  DuoFern network function table
1
   The "WR ConfigTool" software can be downloaded from our website at www.rademacher.de
*   Only available via radio
**   Not supported by Troll Basic DuoFern.
#   only with Venetian blinds mode activated