Dok. Nr. 03 0009 01 D 
Function 
 
PC Module 
Module PC 
Parameter xxxx 
Set PWM 
(Charging current) 
 
!n 12 xxxx 
>n 12 
0000 
6A 
0001 
10A 
0002 
13A  
0003 
16A 
0004 
20A 
0005 
30A 
0006 
32A  
0007 
63A  
0008 
70A  
0009 
80A  
0010 
Default charging current 
0080..0970 direct 8%...97% 
0999 
charging not allowed 
PWM enabled 
!n 13 
>n 13 
 
PWM disabled 
!n 14 
>n 14 
 
Set default PWM  
(default charging current) 
!n 15 xxxx 
>n 15 
0000 
6A  
0001 
10A  
0002 
13A  
0003 
16A  
0004 
20A  
0005 
30A  
0006 
32A  
0007 
63A  
0008 
70A  
0009 
80A 
Set marker “ventilation” 
!n 16 111x 
>n 16 
Get marker “ventilation” 
 
!n 17 
>n 17 000x 
ventilation connected 
ventilation not connected 
Set address of module 
!n 22 111x 
>n 22 
Get address of module 
 
!n 23 
>n 23 000x 
1…8 
Address 1…8 
Broadcast/Default 
Load factory settings and 
reset 
!n 24 1111 
>n 01 Vx.y 
Vx.y Firmware Rev. 
Stop charging -or- 
Leave MANUAL 
 
!n 25  
>n 25 
 
Get default PWM (default 
charging current) 
 
!n 26 
>n 26 xxxx 
Default PWM in 0.1%-steps 
I
DEFAULT
 =  
PWM
0.6A resp. (PWM-64)
2.5A 
Set bBreakCharge 
 
!n 27 
>n 27 
Clear bBreakCharge 
 
!n 28 
>n 28 
bBreakCharge=1
 charging procedure 
halted at B1 
Get bBreakCharge 
 
!n 29 
>n 29 xxxx 
0000 
bBreakCharge=0 
0001 
bBreakCharge=1 
Switch to A’ 
 
!n 30 
>n 30 
 
Leave A’ 
 
!n 31 
>n 31 
Switch to A