Idec MT-001 데이터 시트
Developed before the
establishment of international
safety standards.
Compliant with international
safety standards.
Compliant with international
safety standards. Even more
consideration has been
taken into account on opera-
tor safety.
Satisfies the requirements of:
Satisfies the requirements of:
Satisfies the requirements of:
International Safety Standards Requirements
Red-colored, mushroom actuator, with yellow background.
(IEC 60947-5-5; 4.2, ISO 13850; 4.4, IEC 60204-1; 10.7)
Normally closed contacts with a direct opening action
(IEC 60947-5-5; 5.2, IEC 60947-5-1; Annex K)
The emergency stop function shall be maintained by latching of the
The emergency stop function shall be maintained by latching of the
operator until reset manually (IEC 60947-5-5; 6.2, ISO 13850; 4.4)
3
Medical Equipment
Food Processing Equipment
Third
Generation
Second
Generation
First
Generation
Highest Safety
IDEC's Unique Reverse Energy Structure
IDEC's Unique
Reverse Energy Structure
Treadmill/Exercise Equipment
Third-generation
Reverse Energy
Structure
With X series emergency stop switches, the potential energy level of
the latched status is lower than that of normal status. In the event the
switch is damaged due to excessive shocks, the NC contacts will turn
off, thus stopping the machine (patented design).
Operator Stroke
Normal
Latched
Normal
Energy
Latched
High
Low
2nd Generation (conventional)
(machine can
operate)
ON
NC contacts:
NC contacts:
(machine cannot
operate)
OFF
NC contacts are
always on standby
to turn ON
(HAZARDOUS)
3rd Generation
(Reverse Energy Structure)
(machine can
operate)
ON
NC contacts:
NC contacts:
(machine cannot
operate)
OFF
Normal
Latched
Operator Stroke
Normal
Latched
Energy
High
Low
NC contacts are
always on standby
to turn OFF
(SAFE)
Energy Status of Emergency Stop Switches
High functionality with sleek design
X6 series emergency stop switches for various applications