Detail program description - Control adjust
   Servo  test
Function test of Servo 1 … 8
Scroll with the arrow keys of the left or right touch pad to 
the menu item "Servo test" of the multifunction menu: 
Telemetr y
info display
Basic settings
Ser vo display
Code lock
Ser vo test
By briefl y pressing the central 
SET
 key of the right touch 
pad, this menu item opens:
SERVO    TEST
act
off
1 2 3 4 5 6 7 8
0.5s
Any of the inputs 1 ... 8 can be activated for the servo 
test by selecting with the arrow keys of the left or right 
touch pad and then briefl y pressing 
SET
 key of the right 
touch pad. As soon as you have set only one of the 
inputs 1 ... 8 to "active", the following notice appears at 
the bottom of the display screen:
1 2 3 4 5 6 7 8
0.5s
CLR=act./deact.
SERVO    TEST
act
off
Simultaneously pressing the arrow keys 
 or  of 
the right touch pad (CLEAR) would now start and stop 
the servo test for input "1", fo r example, with a cycle 
time of 0.5 s.
To change the cycle time, select the time input fi eld 
with the arrow keys of the left or right touch pad. After 
activation of the input fi eld by briefl y pressing the central 
SET
 key of the right touch pad, the movement cycle 
can be changed in 0.5 s increments between 0.5 s and 
3.0 s using the arrow keys of the left or right touch pad. 
Briefl y pressing the central 
ESC
 of the left touch pad or 
the central 
SET
 key of the right touch pad completes the 
time presetting.
1 2 3 4 5 6 7 8
3.0s
HLD = aktivier t
SERVO    TEST
act
off
The "servo test" function started by simultaneously 
pressing the arrow keys 
 or  of the right touch 
pad (CLEAR) automatically control all servos as though 
the would simultaneously and permanently move the 
corresponding control back and forth between -100 
% and +100 % in the set time. All active mixing and 
coupling functions in the respective model memory, 
therefore, are effective and the servos move within the 
specifi ed servo paths and servo delimitations.
As soon as you have started the servo test by 
simultaneously pressing the arrow keys 
 or  of 
the right touch pad (CLEAR), a window opens:
1 2 3 4 5 6 7 8
3.0s
CLR=act./deact.
Ser vo test act.
SERVO    TEST
act
off
Simultaneously press the arrow keys 
 or  of 
the right touch pad (CLEAR) in order to end the test.
Important notice:
The shut-off of the transmitter does not 
automatically end an active servo test. Therefore, 
always stop a servo test manually BEFORE 
SHUTTING OFF the transmitter, because the servo 
test is otherwise restarted after switching on the 
transmitter again.