Hitachi hard disk 0J11285 500 GB 2.5 " 8 MB 0J11285 데이터 시트
제품 코드
0J11285
Z5K500 OEM Specifications
132
14.35 Sense Condition (F0h : vendor specific)
Command Block Output Registers
Command Block Input Registers
Register
7 6 5 4 3 2 1 0 Register
7 6 5 4 3 2 1 0
Data
- - - - -
-
-
- Data
- - - - - -
-
-
Feature
0 0 0 0 0 0 0 1 Error
...See
Below...
Sector
Count
- - - - -
-
-
- Sector
Count
V V V V V V V V
LBA
Low
- - - - -
-
-
- LBA
Low
- - - - - -
- N
LBA
Mid
- - - - -
-
-
- LBA
Mid
- - - - - -
-
-
LBA
High
- - - - -
-
-
- LBA
High
- - - - - -
-
-
Device
- - - - -
-
-
- Device
- - - - - -
-
-
Command
1 1 1 1 0 0 0 0 Status
...See
Below...
Error Register
Status Register
7 6 5 4 3 2 1 0
7 6 5 4 3 2 1 0
CRC UNC 0
IDN
0
ABT T0N AMN BSY RDY
DF
DSC DRQ COR IDX ERR
0 0 0 V 0 V 0 0
V V V - V - 0 V
Table 105 Sense Condition Command (F0h)
The Sense Condition command is used to sense temperature in a device.
This command is executable without spinning up even if a device is started with No Spin Up option.
If this command is issued at the temperature out of range which is specified for operating condition, the
error might be returned with IDN bit 1.
error might be returned with IDN bit 1.
Output Parameters To The Device
Feature
Feature
The Feature register must be set to 01h. All other value are rejected
with setting ABORT bit in status register.
with setting ABORT bit in status register.
Input Parameters From The Device
Sector Count
Sector Count
The Sector Count register contains result value.
Value Description
00h
Temperature is equal to or lower than -20 degC
01h-FEh
Temperature is (Value / 2 - 20) deg C
FFh
Temperature is higher than 107 degC
N
Not recommendable condition for start up. If over stressed condition
is detected, this bit will be set to one.
is detected, this bit will be set to one.