Programming made easy 
 
6.3 Powerful instructions make programming easy 
 
Easy Book 
106
 
Manual, 03/2014, A5E02486774-AF 
Table 6- 11  TOF (OFF-delay timer) 
LAD / FBD 
SCL 
Timing diagram 
 
"timer_db".TOF( 
    IN:=_bool_in_, 
    PT:=_undef_in_,  
    Q=>_bool_out_,  
    ET=>_undef_out_); 
 
 
 
 
 
 
Table 6- 12  TONR (ON-delay Retentive timer) 
LAD / FBD 
SCL 
Timing diagram 
 
"timer_db".TONR( 
    IN:=_bool_in_, 
    R:=_bool_in_ 
    PT:=_undef_in_, 
    Q=>_bool_out_, 
    ET=>_undef_out_); 
 
 
 
 
 
 
 
Table 6- 13  Preset timer -(PT)- and Reset timer -(RT)- coil instructions 
LAD 
Description 
 
Use the Preset timer -(PT)- and Reset timer -(RT)- coil instructions with either box or coil timers. These 
coil instructions can be placed in a mid-line position. The coil output power flow status is always the same 
as the coil input status.  
 
When the -(PT)- coil is activated, the PRESET time element of the specified IEC_Timer DB data is set 
to the "PRESET_Tag" time duration. 
 
When the -(RT)- coil is activated, the ELAPSED time element of the specified IEC_Timer DB data is 
reset to 0.