Exchanging a V3.0 CPU for a V4.0 CPU 
 
B.1 Exchanging a V3.0 CPU for a V4.0 CPU 
 
Easy Book 
346
 
Manual, 03/2014, A5E02486774-AF 
Web server 
If you exchange a V3.0 CPU for a V4.0 CPU, your Web server project settings for activating 
the Web server and whether or not to require HTTPS access will be the same as they were 
in V3.0. You can then configure users, privileges, passwords (Page 193), and languages as 
needed to use the Web server. If you do not configure users with additional privileges, then 
you are limited as to what you can view from the standard Web pages (Page 194). The S7-
1200 V4.0 CPU does not support the former pre-configured "admin" user and password. 
Formerly, the Data log Web server page provided a "Download and Clear" operation. The 
V4.0 Web server File browser page (Page 194), from which you access data logs, no longer 
provides this feature. Instead, the Web server provides the ability to download, rename, and 
delete data log files. 
Transfer card incompatibility 
You cannot use a V3.0 transfer card (Page 58) to transfer a V3.0 program to a V4.0 CPU. 
You must open the V3.0 project in STEP 7, change the device to a V4.0 CPU (Page 74), and 
download the STEP 7 project to your V4.0 CPU. After you have changed your project to a 
V4.0 project, you can then make a V4.0 transfer card for subsequent program transfers. 
GET/PUT communication 
By default, GET/PUT communication was enabled in V3.0. When you replace your V3.0 
CPU with a V4.0 CPU (Page 74), you see a message in the compatibility information section 
stating that GET/PUT is enabled. 
Motion control support 
S7-1200 V4.0 CPUs do not support the V1.0 and V2.0 motion libraries. If you perform a 
device exchange for a STEP 7 project with V1.0 or V2.0 motion libraries, the device 
exchange substitutes compatible V3.0 motion control instructions (Page 217) for the V1.0 or 
V2.0 motion library instructions at compile. 
If you perform a device exchange for a STEP 7 project that contains two different motion 
control instruction versions (V3.0 and V4.0), the device exchange substitutes compatible 
V4.0 motion control instructions (Page 217) at compile. 
During a device exchange from V3.0 to V4.0, the motion control Technological Object (TO) 
version automatically changes to V4.0. The TO structure is different between V3.0 and V4.0. 
All associated blocks change as well. Block interfaces, watch tables, and traces update to 
the new V4.0 structure. You can find the differences between the V3.0 and V4.0 motion 
control axis parameters in the following two tables: 
 
V3.0 
V4.0 
Config.General.LengthUnit 
Units.LengthUnit 
Config.Mechanics.PulsesPerDriveRevolution 
Actor.DriveParameter.PulsesPerDriveRevolution 
Config.Mechanics.LeadScrew 
Mechanics.LeadScrew 
Config.Mechanics.InverseDirection 
Actor.InverseDirection 
Config.DynamicLimits.MinVelocity 
DynamicLimits.MinVelocity