4.4 Memory areas, addressing and data types
Easy Book
66
Manual, 03/2014, A5E02486774-AF
Declaration
To overlay a parameter, declare an additional parameter directly after the parameter that is
to be overlaid and select the data type "AT". The editor creates the overlay, and you can
then choose the data type, struct, or array that you wish to use for the overlay.
Example
This example shows the input parameters of a standard-access FB. The byte tag B1 is
overlaid with an array of Booleans:
Table 4- 5
Overlay of a byte with a Boolean array
7
6
5
4
3
2
1
0
AT[0]
AT[1]
AT[2]
AT[3]
AT[4]
AT[5]
AT[6]
AT[7]
Another example is a DWord tag overlaid with a Struct:
The overlay types can be addressed directly in the program logic:
LAD
FBD
SCL
IF #AT[1] THEN
...
END_IF;
IF (#DW1_Struct.S1 =
W#16#000C) THEN
...
END_IF;
out1 := #DW1_Struct.S2;