Intel 1.30 GHz YA80543KC0133M 사용자 설명서

제품 코드
YA80543KC0133M
다운로드
페이지 108
90
Datasheet 
System Management Feature Specifications
6.7.5
Conversion Rate Register
The contents of the conversion rate register determine the nominal rate at which analog-to-digital 
conversions happen when the thermal sensing device is in auto-convert mode. 
 shows 
the mapping between conversion rate register values and the conversion rate. As indicated in 
, the conversion rate register is set to its default state of 02h (0.25 Hz nominally) when 
the thermal sensing device is powered-up. There is a ±25% error tolerance between the conversion 
rate indicated in the conversion rate register and the actual conversion rate.
Table 6-16. Thermal Sensing Device Conversion Rate Register
Register Contents
Conversion Rate (Hz)
00h
0.0625
01h
0.125
02h
0.25
03h
0.5
04h
1
05h
2
06h
4
07h
8
08h to FFh
Reserved for future use