UNINTERRUPTIBLE POWER 
SUPPLIES (UPS)
LIGTHING FLOW DIMMER-
STABILISERS
DC POWER SYSTEMS
STATIC INVERTERS
PHOTOVOLTAIC INVERTERS
VOLTAGE STABILISERS
TECHNICAL SUPPORT & SERVICE 
Covering a wide range of powers from 700 VA to 20 kVA, Salicru’s SLC TWIN PRO series gives maximum reliability in electrical 
protection for businesses and industry. With its double conversion On-line technology, the most reliable technology on the market, 
the SLC TWIN PRO series is a single phase output UPS (with single phase input from 700 VA to 20 kVA and three-phase input 
from 8 kVA to 20 kVA), with an output power factor of 0.9 
(1)
, broad communication options via interface + monitoring/automatic file 
closing shutdown software, batteries for standard autonomy integrated in the cabinet itself, option of extending back-up for processes 
requiring greater available autonomy and options of parallel/redundant operation up to 4 units 
(1)
 for installations growing in qualitative 
and quantitative demands.
Added performances include the standard static and maintenance bypasses 
(1)
, the low input current distortion (THDi) under 5%, 
small footprint in both standard and extended autonomies, full information obtained from the LCD/graphic display or the possibility of 
working in frequency converter mode.
Slc twin pro: the solution for maximum on-line protection
performances
· Double conversion On-line UPS.
· Output power factor = 0.9 (up to 3 kVA = 0.8).
· Input current Total Harmonic Distortion (THDi) <5%.
· Control panel with LCD display or graphic display and keyboard.
· Tower format.
· Option of parallel up to 4 units. 
(1)
· Eco-mode operation.
· Series communications (RS-232) 
(1)
 and USB interfaces.
· Monitoring software for Windows, Unix, Linux and Mac.
· Smart slot for SNMP/relays.
· Extended autonomy available.
· Automatic frequency detector.
· Frequency converter function.
· EPO – Emergency Power Off.
· Maintenance bypass.
 (1)
· Cold Start function for starting from batteries.
. Equipments conversion  easy and fast  from input three phase to 
single phase.
· SLC Greenergy solution.
The largest information losses from computer and telecommunications systems in more than 45% of cases are caused by 
disturbances (blackouts, micro cuts, voltage variations, frequency variations,...) in the mains supply. To the information losses we 
must add the losses caused by the user’s inactivity during the recovery time and the expense of restoring damaged equipment and 
systems.
Salicru’s SLC TWIN PRO series UPS give the best protection for ERP systems, CRM platforms, Business Intelligence (BI), intranets/
extranets,...
Aplicaciones: 
Security and flexibility for single phase systems
Double conversion on-line UpS 700 VA - 20 kVA
SLC TWIN PRO
(1) From 4 kVA
SLC TWIN PRO