Dodge SP600 Series 데이터 시트

다운로드
페이지 4
•  Ramp Control
 
-   2 accel/decel rates
 
-   Frequency avoidance bands (3) 
to lock out mechanical resonance 
points.
 
-   “S” curve acceleration and 
deceleration for smooth speed 
transitions
•  Time Stamped Fault Log
 
-   User Interlock Open
 
-   High DC Bus Voltage
 
-   Low DC Bus Voltage
 
-   Over-Current
 
-   Over-Frequency
 
-   Over-Temperature
 
-   Electronic Motor Overload
 
-   Ground Fault
 
-   Others
•  Option Kits
 
-   Braking resistors
 
-   Remote NEMA 4 operator 
interface
 
-   PC based V*S Utilities
 
-   EMC line filters
 
-   Network communications modules
 
  -  ControlNet
 
  -  DeviceNet
 
  -  Profibus
 
  -  Others
•  Stopping Modes
 
-   DB Braking
 
-   Ramp Stop
 
-   Coast Stop
 
-   DC Injection Braking
•  Operator Interface Modules
 
-   Multi-line, 6-language graphical 
LCD OIM for local or remote 
operation. Allows drive control, 
configuration, monitoring and 
diagnostics. Function keys are 
configurable for desired functions.
•  Drive Protection
 
-   Line-to-line and line-toground and 
output short circuit protection.
Instruction Manuals
•  D2-3485
 
(6SP Series - Frames A, B, C, D)
•  D2-3501
 
(6SB Series - Frames 2, 3, 4, 5, 6)
Service Conditions
•  Elevation to 3300 ft.
 
(1000 meters); Derate 3% for every 
1000 ft. above 3300 ft.
•  Operating temperature ranges:
 
-  NEMA enclosures:
 
  -  0°C to 40°C (external ambient)
 
-  IP20 enclosures:
 
  -  0°C to 50°C
 
    (50 HP - 45°C; 200 HP - 40°C)
 
    (panel ambient)
•  Atmosphere non-condensing relative 
humidity: 5% to 95%
•  AC line voltage variation: rated input 
voltage ±10%
•  AC line frequency variation (50/60 
Hz): 48 - 62 Hz
• Storage temperature:
 
-  - 40°C to 65°C
 
  (-40°F to 149°F)
Application Data
•  Pulse width modulation (PWM) 
sensorless vector control
• Maximum load:
 
-  110% continuous for one minute 
(Normal Duty Rating)
 
-  150% continous for one minute 
(Heavy Duty Rating)
•  Frequency stability long term: 0.01% 
of base speed with digital keypad 
0.5% of base speed with analog 
speed reference.
• Linearity (speed reference to output 
frequency): ± 1.0% 
Quiet Motor Operation Up 
to 200 Feet
• The SP600 controller uses IGBT 
transistors switched at frequencies up 
to 10kHz to reduce PWM induced 
motor audible noise.
• Unique transistor control circuits also 
allow drive to motor distances of 
up to 300 feet when applied with 
Reliance motors before output filtering 
considerations must be applied.
• Tested to ensure that the waveform at 
the motor conduit box will not exceed 
the limits specified in NEMA MG1 
31.40.4.2. at lead lengths of 200 ft.