1) Make sure that the switch is in the off
position.
2)
Disconnect AC and/or DC power cord(s). 
3)
Locate the battery compartment, which is 
next to the silver transceiver on the back 
of the FWT -- see Figure. 7.
NOTE: 
Make sure that the power switch is
in the OFF position.
4)
Remove the battery compartment cover by 
pressing the securing tab downward while 
sliding the lid toward the securing tab.
5)
Position the Phonecell so that the battery 
compartment is closest to you and the sil-
ver transceiver is furthest away from you.
6)
Place an insulator (i.e. paper or
plastic) between the batteries and
silver transceiver -- as shown in
Figure 8. This will prevent the
batteries from damaging the
Phonecell’s transceiver.
Step 4. Optional Battery Installation
DANGER!
Follow these instructions exactly. If the wire leads are not connected
to the proper terminals, the circuit board and/or transceiver may be
damaged. Always observe proper polarity (make sure the colored
wires match) while installing the wire leads and connecting wire.
!
Your Phonecell SX3i has an internal power supply with battery backup that pro-
vides uninterrupted talk time and standby operation in the event of AC power 
failure. The power supply will trickle-charge the batteries while AC power is 
available. However, no recharging occurs during conversation mode. 
The FWT uses two 6-Volt (4.5 Amp. Hr.) batteries (not supplied). Batteries are not
shipped in the unit to prevent damage and to avoid power draining. To install bat-
teries, turn the Phonecell upside down and follow the instructions below:
Battery 
Compartment
Fig. 7
CAUTION!
Do Not allow the battery terminals to touch the silver transceiver
at any time, under any circumstances.
!
Battery
Compartment
Transceiver
Batteries
Fig. 8
Continued...
Power
Switch