HP NetRAID-4M Cluster Services Installation Guide  
Hardware, Drivers and Utilities 
  7
11.  Connect one end of a 10BaseT Crossover cable to the HP D5013B NIC that was just 
installed into Server A.   
12.  DO NOT connect the HP NetRAID-4M controller SCSI cables at this time. 
13.  Repeat the above steps, 1 through 8 to add the HP NetRAID-4M and HP D5013B NIC to 
Server B
14.  Close Server B, and if working on a racked server, slide the server back into the rack 
enclosure, and then reconnect all cables. 
15.  Connect the other end of the 10BaseT Crossover cable to the second HP D5013B NIC in 
Server B. 
CAUTION 
DO NOT connect the HP NetRAID-4M controller SCSI cables at this time. 
Update the NetRAID-4M Firmware 
16.  Flashing from diskette -- At Server A, insert the HP NetRAID-4M firmware update 
diskette in the floppy drive and power the server on.  Do not power on Server B at this 
time. Go to step 17
Or 
 
Flashing from CD-ROM --NetRAID-4M firmware can be flashed without diskettes by 
booting from the HP NetServer Navigator CD-ROM.  The sequence of menu selections is: 
Configure the ServerCustom SetupBIOS and Firmware UpdateHP NetRAID-4M 
Adapter(D9161/D9351A)

 
If the firmware listed under 
Version on server
  IS the latest supported version, remove the 
CD, power off the server, and skip to step 26, otherwise, if the 
Version on CD
 is desired, 
check the box next to HP NetRAID-4M Adapter (D9161/ D9351A), ContinueChoose 
Language
, Continue.  Skip to step 26
17.  When the NetRAID-4M banners on the screen, note the firmware or build version, for 
example: 
NetRAID-4M BIOS v.2.4-0 [Build 4584] 
18.  If the firmware IS the latest supported version, remove the floppy, power off the server, 
and skip to step 26, otherwise, proceed to the next step to update the firmware. 
19.  If prompted with a message that the SCSI IDs are not responding, press Enter
20.  When the server has booted to the HP NetRAID-4M firmware update diskette 1, select 
Update NetRAID Flash Image
21.  Tab to select OK and press Enter to accept A:\ as the directory for the flash image file. 
22.  When prompted, insert the HP NetRAID-4M firmware update diskette 2 into the floppy 
drive of the server and press Enter
CAUTION 
DO NOT power off or reboot the server during the firmware update.  If this 
should occur, the NetRAID-4M card will be made inoperable. 
23.  Select OK to NOT reboot the server.