Bertazzoni 36 Cooktop 5-Burner 사용자 매뉴얼

다운로드
페이지 24
 
5
Wiring diagram: 
see Fig. 10 
Wiring diagram description  
1. Cable terminal 
2. Spark generator 
3. Ignition spark 
L. Black 
N. White 
T. Green (earth) 
 
Room ventilation – Location and venting. 
ATTENTION: An exhaust fan may be used with the appliance; in each case it shall be installed in 
conformity with the national standards in force. 
ATTENTION: Exhaust hood operation may affect other vented appliances; in each case it shall be 
installed in conformity with the national standards in force. 
 
Conversion to different types of gas 
Before carrying out any maintenance work, disconnect the appliance from the gas and electric 
supply. For Natural Gas fit regulator assembly described in Fig. 5. For LP Gas fit assembly described 
in fig. 5. 
 
 - CHANGING THE NOZZLES FOR USE WITH OTHER TYPES OF GAS: 
To change the nozzles of the burners  use the following procedure:  
Lift up the burners and unscrew the nozzles ( Fig. 7) using an adjustable spanner of 7 mm and change the 
nozzles with those designed for the new gas supply according to the information given in TABLE A shown 
below. 
TABLE A: Adapting to different types of gas     
Burner 
Position 
Injector 
Gas 
Pressure 
Max Rate 
Min Rate 
By-pass 
  
  
diam. [mm.] 
Type 
[i.w.c.] 
[BTU/h] 
[W] 
[BTU/h] 
[W] 
diam. [mm] 
0,90 Natural 4"  3400 996  900  264 
Regulated 
Auxiliary 
Front R 
0,54 LP 
(Propane)
11" 
3400 
996 
900 
264  0,29 
Semi- 
Rear L and 
1,18 Natural 4"  6100 1787 1500 439 
Regulated 
Rapid 
0,70 LP 
(Propane)
11" 
6100  1787  1500 
439  0,37 
1,55 Natural 4"  10400 
3047 3700 1084 
Regulated 
Rapid 
Front L 
0,92 LP 
(Propane)
11" 
10400  3047  3700  1084  0,58 
1,65 Natural 4"  11900 
3487 5300 1553 
Regulated 
Triple Ring 
Central 
1,02 LP 
(Propane)
11" 
12300  3604  5300  1553  0,73 
CAUTION: save the orifices removed from the appliance for future use  
Regulation of burners 
Regulation of the "MINIMUM" on the burners 
To regulate the minimum on the burners carry out the following procedure indicated below: 
1) Turn on the burner and put the knob onto position MINIMUM ( small flame ). 
2) Remove the knob ( Fig. 8) of the tap which is set for standard pressure. The knob is found on the bar of 
the tap itself. 
3) Beside the tap bar on the work top, insert a small slotted screwdriver into the hole on the vale rod (Fig. 8) 
and turn the choke screw to the right or left until the flame of the burner is regulated in the most suitable way 
to MINIMUM. 
4) Make sure that that the flame does not go out when changing the position quickly from MAXIMUM to the 
MINIMUM position.  
ATTENTION: The regulation described above can be carried out only with burners using natural gas, 
while with burners using propane gas the screw must be fully screwed in, in a clockwise direction.   
Adaptation of the pressure regulator for use with different type of gas 
The pressure regulator supplied with the appliance is a convertible type pressure regulator for use with 
Natural Gas at a nominal outlet pressure of 4” w.c. or LP gas at a nominal outlet pressure of 11” w.c. and it is 
pre-arranged from the factory to operate with one of these gas/pressure as indicated in the pre-arranging 
labels affixed on the appliance, package and Instruction booklet.