ADIC Tool Storage 6-00025-01 사용자 설명서

다운로드
페이지 132
Accessing Storage Devices
2-4
Library List
6-00025-01 Rev A
Element Addressing
Because ADIC does not support source storage element 
addressing, the AMASS 
medialist
 utility cannot identify the 
home storage slot for volumes in a drive.
To identify and return media from a drive to its home storage 
slot, perform the following steps:
Step 1.
Use the 
mediaread
 utility to read the slot number 
from the label as shown below and display the 
output to the screen: 
FastStor 22
You must configure the library as 22 slots with 
one Import/Export slot. To create this 
configuration with the “Diagnostic Menu” on the 
front panel, use the “CFG SLOTS” function. 
Access the Diagnostic Menu by pressing and 
holding first the NEXT button and then the 
MODE button for about 5 seconds.
† If a power outage, hang, or reboot occurs, power off the ADIC 
libraries, power on the ADIC libraries, and then run the AMASS 
init_element
 utility.
ADIC Scalar 
for Tape
Caveats
# cd /usr/amass/utils
# mediaread drivenumber 0
# cat /tmp/mediaread
Block number
Display output 
to screen