Westinghouse 22 Watt (replaces 32 Watt) T8 Linear LED Light Bulb 0365200 사양 시트

다운로드
페이지 2
t8 Direct install LeD Lamp†
operates with Applicable Ballast
 
sPeCiFiCAtion sheet
Physical Characteristics
Finish ....................................................................................Cool White
Base ......................................................................................g13
MoL ......................................................................................48"
item number
 
03652
specifications
 
energy used (Watts) ................................................... 22
Domestic Code .............................................................. LeD 22t8/48”/35 Direct install 
Volts ................................................................................... 144
Brightness (Lumens) ................................................... 2200
Average Rated hours .................................................. 50,000
Life (in years)*...................................... .......................... 45.6
Light Appearance (Kelvin) ........................................ 3500
CRi ...................................................................................... 85
efficacy (LPW) ............................................................... 100
number of LeD Modules ............................................ 120
Minimum starting temperature ............................... -20°C/-4°F
estimated Yearly energy Cost**...... ........................ $2.65
Package type ................................................................ sleeve
† Dimmable when used with applicable ballast.
 
 
 
Limited Warranty 
This lamp is warranted to be free from defects in material and workmanship for 3 years (based on using 3 hours per day).
Warning
•  Turn power off before inspection, installation, or removal.
•  Risk of electric shock - Do not use where exposed to water or weather.
•  Not for use in totally enclosed luminaires.
•  Do not open – no user serviceable parts inside.
•  This device is not intended for use with emergency exit luminaires or emergency exit lights.
•  This device complies with Part 15 of the FCC rules and has been tested and found to comply with the limits for a Class B digital device. These limits are designed to provide reasonable protection against  
  harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause    
  harmful interference to radio communications. Any changes or modifications not expressly approved by the manufacturer could void the user's authority to operate the equipment.
  * Based on 3 hrs./day
** Based on 3 hrs./day 11¢/kWh - Cost depends on rates and use.
see reverse side for ballast compatibility.
mercury
NO