RS232 Port Interface:  16 RS232 serial inputs use DB9 connectors configured as DTE
ports.
●   
Network Interface:  10Base-T Ethernet, RJ45
●   
Coding:  Asynchronous, 7/8 bits ASCII.
●   
Parity:  Even, Odd, None
●   
Stop Bits:  1 or 2.
●   
Data Rate:  300 to 115.2K bps (all standard rates).
●   
Flow Control:  XON/XOFF, RTS/CTS, Both, or None.
●   
Timeout:  No activity timeout disconnects port.  1, 5, 10, 15, 30 seconds, 1, 5, 15, 30, 90
minutes.
●   
Memory:  Stores Parameters and captured data. Non-volatile 512K SRAM buffer
memory.  Statically allocated.
●   
Break:  Accept Break or Refuse Break
●   
Option Switch:  8 position DIP switch, selects default settings for baud rate, flow control,
response message format, and command echo.
●   
LEDs:  Power On, Ready, Net, Data Activity for Ports 1 through 16.
●   
Temperature:  0°C to 45°C (operating)
●   
Power:
AC Version:  IEC-32 Inlet, 115/230 VAC, 50/60 Hz, 5 watts
❍   
DC Version:  Terminal Strip (#6-32), -48 VDC, 0.2 Amp Max.
❍   
●   
Size:  2.8" x 17" x 6.8" (H x W x D)
●   
Weight:  8 lbs. shipping weight
●   
Humidity:  10 to 90% RH, Non-Condensing
●   
Venting:  Side vents are used to dissipate heat generated within the unit. When mounting
the unit in an equipment rack, make certain to allow adequate clearance for venting.
●   
Appendix C.   Customer Service
Customer Service hours are from 8:00 AM to 5:00 PM, PST, Monday through Friday.  When
calling, please be prepared to give the name and make of the unit, its serial number and a
description of its symptoms.  If the unit should need to be returned for factory repair it must be
accompanied by a Return Authorization number from Customer Service.
WTI Customer Service
5 Sterling
Irvine, California   92618
949-586-9950
Toll Free:  1-800-854-7226
Email: